KLJUČNE BESEDE: funkcionalna električna stimulacija, večelektrodni sistem, platinske elektrode, mielinizirana živčna vlakna, periferno živčevje, električno polje, biokibernetika POVZETEK: Razvitje bil večelektrodni sistem za zunajživčno stimulacijo živčnih vlaken. Sestavljen je iz štirinajstih stimulacijskih elektrod iz platine ovite z izolacijskim listom iz biokompatibllne snovi v obliki spirale v prečnem preseku. Razvoj je temeljil na rezultatih ob histoloških preiskavah perifernih živcev, ki naj bi jih stimulirali in modelih aktivizacije mieliniziranih živčnih vlaken. Število stimulacijskih elektrod, ki so aktivirane,je odvisno od premera živca, ki ga stimuliramo. Debelejši živci avtomatsko aktivirajo več elektrod, kot tanjši. KEYWORDS: functional electrical stimulation, multielectrodecuff, peripheral nerves, platinum myelionated nerve fibers, electric field, biocybernetics ABSTRACT: A multielectrode nerve cuff for extraneural selective stimulation of nerve fibers has been developed.lt consists of fourteen platinum stimulation electrodes embedded within a self^curling sheet of biocompatible isolation exhibiting a spiral transverse cross section. Development wa& based on results obtained by hystological examination of peripheral nerves planned to be stimulated and on models of excitation of myelinated nerve fibers. The number of stimulating electrodes which are activated depends on the diameter of the stimulated nerve. Nerves with greater diameter automatically activate more electrodes than thin ones. INTRODUCTION Functional Neuromuscular Stimulation (FNS) is based on electrical excitation of the myelinated fiber starts by imposing a sufficiently large voltage gradient over the Ranvier nodes inafiber in the axial direction. In literature, models of nen/e stimulation can be found (1,3,8,10). They describe excitation of myelinated nen/e fiber during nerve stimulation when all parameters are known. Introduction of the models of the effects of electric field on myelinated nerve can be useful for the design of electrodes and electrical parameters in FNS. Models calculate and evaluate potential fields around electrodes, excitatory mechanisms and choice of electrode sites (6,9). For many aplications using implanted electrodes it is important to know how many fibers could be activated by a given current signal. A simple rule is that distant fibers need stronger currents in order to be stimulated and the number of firing fibers increases with the strength of stimulation signal (2,4,7).The ideal stimulating electrodes should be able to activate individual or small groups of neural fibers within a fascicular bundle, for example, in a motor nerve. One of the possible approaches is selecting of the extraneural electrodes while the other is used for the intraneural electrodes. In both the realization of clinical systems to effect electrical activation of paralyzed muscles depends strongly on the development of electrodes that have realible,selective and reproducible muscle force recruitment characteristics. The nonhomogenity, anizotropy, and poorly de- fined geometry of biological media set very serious limitations on design of such stimulation multielectrode arrays. Selective stimulation of fibers or small groups in peripheral nerves needs the development of multielectrode arrays. A possibility created by the use of multielectrode configurations for selective nerve stimulation is the independent control of groups of motor neuron fibers belonging to muscles or muscle groups with different functions. In this situation the motoneuron groups recruited by different electrodes should also belong to different muscles or muscle groups (6,9). Selective stimulation of fascicle in the middle of the multifascicle nerve is best with intrafascicular electrode and worse with extraneural electrode (9). However, with extraneural electrode, selective stimulation of superficial fascicles near the electrode seems to be possible. It was shown that with an extraneural electrode parts of fascicle closest to the electrode are recruited, as shown experimentally by McNeal and Bowman (6).Consequently,multielectrode configurations can be used for stimulating different muscles from the same nerve. In spite of the fact of inverse recruitment found for extraneural electrodes by Petrofs-ky. Fang and Mortimer, and Veltink (2,7,9) and the fact that it is hardly possible to achieve stable, selective stimulation of fibers from outside the nerve, we decided to develop a multielectrode system for extraneural stimulation. Such a decision was based upon the request for minimization of neural damage which can occur by using intraneural or intrafascicular electrodes. METHODS A muitielectrode cuff with a spiral transverse crosssec-tion for extraneural selective stimulation of nerve fibers was designed to be expandable so that it could be sized to fit around a nerve (5). It was designed to be simple to install on the nerve trunk without the use of sutures. The cuff is manufactured by bonding two flexible silicone sheets together. One sheet is streched and fixed in that position; an adhesive layer is spread over the streched sheet while a second unstreched sheet is placed on top of the adhesive and the composite is compressed to a constant thickness. The cuff having been released, curls into a spiral tube as the streched sheet contracts to its natural rest lenght. The diameter of the cuff is related to the amount of the stretch,the smaller the diameter. Fourteen electrodes with geometric surface of 2 mm^ made of thin platinum ribbon (99.99 % purity) together with lead wires are then mounted on the third reinforced silicone sheet and bonded on the inner side of the mechanically opened spiral cuff. The completed muitielectrode cuff is then cut from the bonded sheets and trimmed to appropriate lenght as shown in Figure 1. RESULTS Small electrodes of the muitielectrode cuff are needed to effect selective activation of small groups of the nerve fibers. However it is necessary to depolarize axons at some distances from the electrode, and consequently it is desirable to be able to inject enough charge without tissue damage and electrode corrosion. The electromechanical technique of cyclic voltammetry was used to delineate an operational potential window between hydrogen and oxygen evolution in a protein containing solution. In Figure 2 is a cyclic voltammogram of one electrode showing the potentials at which reversible surface reaction occur. Hydrogen evolution began at about -0.8 V, oxidation of the absorbed hydrogen appea- red when the potential was changed in positive direction at about -0.7 V. Oxidation of the electrode surface and decomposition of water started at about 1.0 V. DISCUSSION The cuff was designed to enaole monopolar, bipolar and multipolar extraneural stimulation of the peripheral nerve. In the monopolar type, the neutral common anode can be situated elsewhere in the vicinity of the muitielectrode cuff, while each of the stimulating electrodes can be connected to one of the stimulating channels alone or in any combination with the other electrodes. In bipolar and multipolar type, each of the stimulating electrodes can be used as stimulating or neutral electrodes or in all possible combinations with other electrodes of the muitielectrode system. Consequently, there is a great possibility of creating different electrical fields around the nerve for the aim of activating desired fibers or small groups. For the muitielectrode cuff important factors relating to safety, such as chemical composition, mechanical flexibility, geometric configuration, and size, were considered during manufacturing. Accepted bio-materials such as medical grade Silastic and Teflon, type 316 stainless steel, and platinum were used in cuff manufacture. Animal experiments with the goal of getting information on selectivity, sensitivity and stability of stimulation using such system are in preparation. REFERENCES 1) Coburn, B. and Sin, W. K.: A theoretical study of epidural electrical stimulation of the spinal cord - Part 1: Finite element analysis of stimulus field. IEEE Trans. Blomed.Eng., vol. BME- 32, pp. 971-977, 1985 2) Fang, Z.- P. and Mortimer, J. T.: A method for attaining natural recruitment order in artificially activated muscles. Proc. 9th Fig. 1: A muitielectrode cuff of extraneural selective stimulation of nerve fibers. Fig. 2: Cyclic voltammogram of one Pt electrode Sweep rate: 0.5 V/sec. Electrolyte: Eiiott's buffered solution, plH 7.3. Ann.Conf. IEEE Eng. In Med. & Blol. Soc., Boston, 13th-16th Nov. 1987, 657-658,1987 3) Ganapathy, N.,Clark, J.;Extracellular currents and potentials of the active myelinated nerve fiber.Biophys. J.,Vol. 52,pp. 749-761,1987 4) Gorman, P. H. and Mortimer, J. T.: The effect of stimulus parameters on the recruitment characteristics of direct nerve stimulation, IEEE Trans.Biomed. Eng., Vol. BME-30, pp. 407-414,1983 5) Naples, G. G., Sweeny, J. D. and Mortimer, J. T. (inventors): Implantable cuff. Method and manufacture and method of instalation. U.S. Patent #4, 602, 624 July 29, 1986 6) Mc Neal, D. R. and Bowman, B. R.: Selective activation of muscles using peripheral nerve electrodes. Med. & Biol. Eng. & Comput, vol.23, pp. 249-253,1985 7) Petrofsky, J. S. and Phillips, C. A.: Impact of recruitment order in electrode design for neural prosthestics of sceletal muscle. American Journal of Physical Medicine, vol.60, pp. 243- 253, 1981 8) Rattay, F.: Analysis of models for external stimulation of axons, IEEE Trans. Biomed. Eng., vol. BME-33, pp. 974-977, 1986 9) Veltink, P. H., Van Alste, J. A. and Boom, H.B.K.: Simulation of intrafascicular and extraneural nerve stimulation. IEEE Trans. Biomed. Eng., vol.BME-53, pp. 69-75, 1989 10) Veltink, P. H., Van Veen, B. K., Struijk, J.J., Holsheimer, J. and Boom, H.B.K.: A model study of nerve fascicle stimulation.IEEE Trans.Biomed. Eng., vol.BME36, pp. 683-692, 1989 Mag. J. Rozman, dipl. ing. Laboratorij za biokibernetiko, Oddelek za biokibernetiko in robotiko, Institut Jožef Stefan, Univerza v Ljubljani, Jamova 39, Ljubljana Republika Slovenija Prispelo: 15. 01. 1992 Sprejeto: 10. 03. 1992