<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-AY5N1JOY/9f952a04-8fcb-4c65-9ae3-7fae1d622450/PDF"><dcterms:extent>330 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-AY5N1JOY/32139b69-7bfb-4e43-82df-4bcdef6317b3/TEXT"><dcterms:extent>0 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="2005-2025"><edm:begin xml:lang="en">2005</edm:begin><edm:end xml:lang="en">2025</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:doc-AY5N1JOY"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/URN:NBN:SI:spr-OTYUOTZX" /><dcterms:issued>2019</dcterms:issued><dc:creator>Sašek, Matic</dc:creator><dc:creator>Smajla, Darjan</dc:creator><dc:creator>Spudić, Darjan</dc:creator><dc:format xml:lang="sl">številka:3/4</dc:format><dc:format xml:lang="sl">letnik:67</dc:format><dc:format xml:lang="sl">str. 195-202</dc:format><dc:identifier>ISSN:0353-7455</dc:identifier><dc:identifier>COBISSID:5638833</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-AY5N1JOY</dc:identifier><dc:language>sl</dc:language><dc:publisher xml:lang="sl">Fakulteta za šport</dc:publisher><dcterms:isPartOf xml:lang="sl">Šport (Ljubljana)</dcterms:isPartOf><dc:subject xml:lang="en">balance</dc:subject><dc:subject xml:lang="sl">ponovljivost</dc:subject><dc:subject xml:lang="sl">protokol</dc:subject><dc:subject xml:lang="sl">ravnotežje</dc:subject><dc:subject xml:lang="en">reliability</dc:subject><dc:subject xml:lang="en">repeatibility</dc:subject><dc:subject xml:lang="en">sport</dc:subject><dc:subject xml:lang="sl">šport</dc:subject><dc:subject xml:lang="en">testing</dc:subject><dc:subject xml:lang="sl">Y-test</dc:subject><dc:subject xml:lang="sl">zanesljivost</dc:subject><dcterms:temporal rdf:resource="2005-2025" /><dc:title xml:lang="sl">Merske značilnosti skrajšanega protokola meritev dinamičnega ravnotežja z napravo Y-test|</dc:title><dc:description xml:lang="sl">The aim of the study was to access intra- and inter-visit reliability of the custom-made Y-balance test device parameters. It was developed to standardise the modified "Star Excursion Balance Test", improve its practicality, and make it commercially available. An individual%s reaching distance in a given direction was found to be correlated with his or her reaching distance in the other 7 directions. This has led to the recommendation that only 3 reach directions (anterior, posteromedial, and posterolateral) should be performed. In comparison to other studies, shorter, though timesaving testing protocol was developed. Reliability was checked using intraclass correlation coefficient, standard error of measurement and smallest real difference parameters. 30 PE students volunteered to participate in the study. The study was designed in a test-retest manner. On every visit, participants executed 2 measuring sets. Paired samples t-test showed some significant differences among inter- and intra-visit results, that is in one third and one half of all parameters analysed, respectively. ICC showed fair to excellent reliability (ICC 0,524-1,000), excluding results in posteromedial direction (ICC &lt; 0,5). Standard error of measurement values ranged 0,014-5,808 cm and values of smallest real difference ranged 0,5-16 %. We noticed no differences between using the maximal distance achieved or average value of two consecutive measures parameters. We found our testing protocol and parameters useful in sports performance, specifically in dynamic balance and contralateral lower limb differences testing. Due to a higher standard error of measurement and a relatively high smallest real difference in posteromedial distance results, we agree that clinical practice usefulness should be questioned. Consistency of the testing protocol and reliability parameters should be considered when testing and, later, interpreting testing results</dc:description><dc:description xml:lang="sl">Namen predstavljene študije je bil preveriti znotrajobiskovno in medobiskovno zanesljivost merskih parametrov na izdelani napravi, ki smo jo poimenovali Y-test. Testni protokol Y-testa izhaja iz, v praksi pogosteje uporabljenega, "Star Excursion" testa, ki pa je za merilca težje izvedljiv in časovno potratnejši. Iz korelacij med rezultati dosegov v osmih različnih smereh je bilo namreč ugotovljeno, da z minimalno izgubo veljavnosti meritev, sposobnosti preiskovanca lahko izmerimo samo v treh dosežnih smereh, tj. anteriorni, posteromedialni in posterolateralni. V primerjavi z ostalimi študijami na tem področju smo ustvarili krajši meritveni protokol in z izbranimi koeficienti preverili njegovo zanesljivost. V študiji je sodelovalo 30 študentov Fakultete za šport. Preiskovanci so opravili prve (test) in druge (retest) meritve v razmiku treh tednov, znotraj katerih so bile izvedene 3 ponovitve testa. T-test za odvisne vzorce je pokazal značilno različne rezultate v tretjini analiziranih parametrov znotraj obiska in polovici analiziranih parametrov med obiskoma. Koeficienti medobiskovne zanesljivosti so pokazali srednje veliko do odlično zanesljivost parametrov (ICC 0,524-1,000) z izjemo rezultatov v posteromedialni smeri (največja in povprečna vrednost pri levi nogi; ICC &lt; 0,5). Standardna napaka meritve se je med obiskoma gibala od 0,014 do 5,808 cm, najmanjša zaznana sprememba pa 0,5-16 %. Med izbranimi največjimi vrednostmi in povprečju vrednosti meritev nismo opazili razlik v vrednostih izračunanih parametrov. Prednost testa in ustvarjenega protokola meritev se je pokazala v njegovi enostavni in hitri izvedbi. Testna izvedba in izbrani parametri so uporabni v športno-diagnostične namene kot hiter način merjenja dinamičnega ravnotežja in kontralateralnih razlik v spodnjih okončinah ter nekoliko manj za klinične namene zaradi ugotovljene večje standardne napake meritev in posledično večje najmanjše zaznane spremembe. Merilec mora med izvedbo testiranj poskrbeti za doslednost pri izvedbi protokola in rezultate meritev interpretirati z ozirom na predstavljene zanesljivostne parametre</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:doc-AY5N1JOY"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:doc-AY5N1JOY" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:doc-AY5N1JOY/9f952a04-8fcb-4c65-9ae3-7fae1d622450/PDF" /><edm:rights rdf:resource="http://rightsstatements.org/vocab/InC/1.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Univerza v Ljubljani, Fakulteta za šport</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:doc-AY5N1JOY/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:doc-AY5N1JOY" /></ore:Aggregation></rdf:RDF>