<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-84TW4TPZ/2ec9d4e3-e5e7-44ce-a20b-371949153e66/PDF"><dcterms:extent>348 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:doc-84TW4TPZ/4eab9b8c-ff83-4d97-981c-fdb3455137dc/TEXT"><dcterms:extent>12 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="1985-2025"><edm:begin xml:lang="en">1985</edm:begin><edm:end xml:lang="en">2025</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:doc-84TW4TPZ"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/URN:NBN:SI:spr-Z2J12Z6C" /><dcterms:issued>2003</dcterms:issued><dc:creator>Bunc, Matjaž</dc:creator><dc:creator>Rozman, Janez</dc:creator><dc:format xml:lang="sl">številka:1</dc:format><dc:format xml:lang="sl">letnik:33</dc:format><dc:format xml:lang="sl">str. 38-40</dc:format><dc:identifier>ISSN:0352-9045</dc:identifier><dc:identifier>COBISSID:16680665</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-84TW4TPZ</dc:identifier><dc:language>en</dc:language><dc:publisher xml:lang="sl">Strokovno društvo za mikroelektroniko, elektronske sestavne dele in materiale</dc:publisher><dcterms:isPartOf xml:lang="sl">Informacije MIDEM</dcterms:isPartOf><dc:subject xml:lang="en">Electromyography</dc:subject><dc:subject xml:lang="sl">Elektromiografija</dc:subject><dc:subject xml:lang="sl">kontrakcija</dc:subject><dc:subject xml:lang="sl">merjenje</dc:subject><dc:subject xml:lang="sl">mišice</dc:subject><dc:subject xml:lang="sl">Mišična kontrakcija</dc:subject><dc:subject xml:lang="en">Muscle Contraction</dc:subject><dc:subject xml:lang="sl">senzorji</dc:subject><dc:subject xml:lang="sl">sila</dc:subject><dc:subject xml:lang="sl">Spreminljevalci</dc:subject><dc:subject xml:lang="en">Transducers</dc:subject><dcterms:temporal rdf:resource="1985-2025" /><dc:title xml:lang="sl">Sensor of forces in small volume contracting tissues| Senzor sile za meritve krčenja drobnih mišic|</dc:title><dc:description xml:lang="sl">A single-channel sensor intended for measurement of forces in small volume contracting tissues within the range of mN was designed, developed and experimentally tested. The force sensor was made up of a Wheatstone bridge composed of four semi-conductor strain gauges bonded on a specially designed cantilever with a handle and metallic cover to protect them. The natural frequency of the sensor is 350Hz while the compliance is 5.7X10-6m/mN. The sensor represents a very linear dependence of the output voftage upon the load. The sensibility of the sensor, at a bridge excitation voltage of 5V, is 0.5mV/mN and the nominal range of the sensor is 0-70mN. Results show that the sensor enables almost isometric measurements of forces in contracting tissues.The results also show that the sensor measures forces with a frequencyof up to 300Hz with appropriate accuracy. Finally, the sensor is suitable for isometric measurements of forces in all types of contracting tissues</dc:description><dc:description xml:lang="sl">Izdelali in testirali smo enokanalni mehansko-elekrični pretvomik za meriive moči krčenja drobnih mišic. Senzor sile je izdelan iz štirih polprevodniških strain-gaugov povezanih v Wheatstonov mostiček, pritrjenih na rigidno merilno ročico ter zaščitenih s kovinskim oklepom. Naravna frekvenca senzorja je 350 Hz in podajnost 5.7 x 10-6 m/mN popolnoma ustreza za meritve skoraj izometričnega krčenja drobnih mišičnih tkiv (&lt;5 N, &lt;50 Hz). Občutljivost senzorja z napajanjem 5 V je v razponu 0-70 mN lineama, 0.5 mV/mN. Testiranja so pokazala, da je mogoče s senzorjem zadovoljivo meriti tudi krčenja s frekvenco blizu 300 Hz. Merilec je primeren za meritve sile izometričnega krčenja različnih krčljivih tkiv</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:doc-84TW4TPZ"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:doc-84TW4TPZ" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:doc-84TW4TPZ/2ec9d4e3-e5e7-44ce-a20b-371949153e66/PDF" /><edm:rights rdf:resource="http://rightsstatements.org/vocab/InC/1.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Strokovno društvo za mikroelektroniko, elektronske sestavne dele in materiale</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:doc-84TW4TPZ/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:doc-84TW4TPZ" /></ore:Aggregation></rdf:RDF>