<Record><identifier xmlns="http://purl.org/dc/elements/1.1/">URN:NBN:SI:doc-2ON98AS2</identifier><date>2019</date><creator>Pečenko, Robert</creator><relation>documents/doc/2/URN_NBN_SI_doc-2ON98AS2_001.pdf</relation><relation>documents/doc/2/URN_NBN_SI_doc-2ON98AS2_001.txt</relation><format format_type="type">article</format><format format_type="issue">letn. 68</format><format format_type="extent">str. 13-18</format><identifier identifier_type="ISSN">0017-2774</identifier><identifier identifier_type="COBISSID_HOST">8675937</identifier><identifier identifier_type="URN">URN:NBN:SI:doc-2ON98AS2</identifier><language>slv</language><publisher>Zveza društev gradbenih inženirjev in tehnikov Slovenije</publisher><source>Gradbeni vestnik</source><rights>BY-NC-SA</rights><subject language_type_id="eng">char front temperature</subject><subject language_type_id="eng">charring of wood</subject><subject language_type_id="slv">dvofazni model</subject><subject language_type_id="slv">oglenenje lesa</subject><subject language_type_id="slv">piroliza lesa</subject><subject language_type_id="eng">pyrolysis of wood</subject><subject language_type_id="slv">temperatura oglenenja</subject><subject language_type_id="eng">two-phase modeluvod</subject><title>Dvofazni toplotno-pirolizni model za določitev oglenenja lesa</title><title>Two-phase thermo-pyrolysis model to determine charring of wood</title></Record>