{"?xml":{"@version":"1.0"},"edm:RDF":{"@xmlns:dc":"http://purl.org/dc/elements/1.1/","@xmlns:edm":"http://www.europeana.eu/schemas/edm/","@xmlns:wgs84_pos":"http://www.w3.org/2003/01/geo/wgs84_pos","@xmlns:foaf":"http://xmlns.com/foaf/0.1/","@xmlns:rdaGr2":"http://rdvocab.info/ElementsGr2","@xmlns:oai":"http://www.openarchives.org/OAI/2.0/","@xmlns:owl":"http://www.w3.org/2002/07/owl#","@xmlns:rdf":"http://www.w3.org/1999/02/22-rdf-syntax-ns#","@xmlns:ore":"http://www.openarchives.org/ore/terms/","@xmlns:skos":"http://www.w3.org/2004/02/skos/core#","@xmlns:dcterms":"http://purl.org/dc/terms/","edm:WebResource":[{"@rdf:about":"http://www.dlib.si/stream/URN:NBN:SI:DOC-ICZ4JTEX/889c8255-5157-4ba6-bed4-f9a20dbc2c86/PDF","dcterms:extent":"1141 KB"},{"@rdf:about":"http://www.dlib.si/stream/URN:NBN:SI:DOC-ICZ4JTEX/ed7c1ee0-fb17-4a37-b9c9-b84e7c375ad2/TEXT","dcterms:extent":"0 KB"}],"edm:TimeSpan":{"@rdf:about":"1999-2025","edm:begin":{"@xml:lang":"en","#text":"1999"},"edm:end":{"@xml:lang":"en","#text":"2025"}},"edm:ProvidedCHO":{"@rdf:about":"URN:NBN:SI:DOC-ICZ4JTEX","dcterms:isPartOf":[{"@rdf:resource":"https://www.dlib.si/details/URN:NBN:SI:spr-6QOUKQ9A"},{"@xml:lang":"sl","#text":"Strojniški vestnik"}],"dcterms:issued":"2023","dc:creator":["Alsakarneh, Amjad","Momani, Lina","Tabaza, Taha"],"dc:format":[{"@xml:lang":"sl","#text":"letnik:69"},{"@xml:lang":"sl","#text":"številka:9/10"},{"@xml:lang":"sl","#text":"str. 401-408"}],"dc:identifier":["ISSN:0039-2480","DOI:10.5545/sv-jme.2023.597","COBISSID_HOST:168717827","URN:URN:NBN:SI:doc-ICZ4JTEX"],"dc:language":"en","dc:publisher":{"@xml:lang":"sl","#text":"Zveza strojnih inženirjev in tehnikov Slovenije etc."},"dc:subject":[{"@xml:lang":"en","#text":"coefficient of performance"},{"@xml:lang":"sl","#text":"hladilni cikli"},{"@xml:lang":"sl","#text":"hladilno število"},{"@xml:lang":"en","#text":"Matlab/Simulink"},{"@xml:lang":"en","#text":"refrigeration cycles"},{"@xml:lang":"en","#text":"Takagi-Sugeno-Kang"}],"dcterms:temporal":{"@rdf:resource":"1999-2025"},"dc:title":{"@xml:lang":"sl","#text":"Fuzzy and Matlab/Simulink modelling of the air compression refrigeration cycle|"},"dc:description":{"@xml:lang":"sl","#text":"The coefficient of performance (COP) for a gas refrigeration cycle was estimated using Matlab/Simulink and fuzzy logic. A Matlab/Simulink model of the gas refrigeration cycle was developed, and the output was compared to theoretical data. Additionally, fuzzy logic was used to estimate the COP for arbitrary low- and high-pressure levels. Simulation results were used to develop a multi-input-multi-output (MIMO) fuzzy Takagi-Sugeno-Kang (TSK)-based model. Both the Matlab/Simulink and the MIMO fuzzy model were found to be very well correlated with theoretical results, with an error of less than 2 %. These results demonstrate the effectiveness of using fuzzy logic to analyse gas refrigeration cycles and suggest that this approach can be extended to analyse other thermodynamic cycles"},"edm:type":"TEXT","dc:type":[{"@xml:lang":"sl","#text":"znanstveno časopisje"},{"@xml:lang":"en","#text":"journals"},{"@rdf:resource":"http://www.wikidata.org/entity/Q361785"}]},"ore:Aggregation":{"@rdf:about":"http://www.dlib.si/?URN=URN:NBN:SI:DOC-ICZ4JTEX","edm:aggregatedCHO":{"@rdf:resource":"URN:NBN:SI:DOC-ICZ4JTEX"},"edm:isShownBy":{"@rdf:resource":"http://www.dlib.si/stream/URN:NBN:SI:DOC-ICZ4JTEX/889c8255-5157-4ba6-bed4-f9a20dbc2c86/PDF"},"edm:rights":{"@rdf:resource":"http://rightsstatements.org/vocab/InC/1.0/"},"edm:provider":"Slovenian National E-content Aggregator","edm:intermediateProvider":{"@xml:lang":"en","#text":"National and University Library of Slovenia"},"edm:dataProvider":{"@xml:lang":"sl","#text":"Univerza v Ljubljani, Fakulteta za strojništvo"},"edm:object":{"@rdf:resource":"http://www.dlib.si/streamdb/URN:NBN:SI:DOC-ICZ4JTEX/maxi/edm"},"edm:isShownAt":{"@rdf:resource":"http://www.dlib.si/details/URN:NBN:SI:DOC-ICZ4JTEX"}}}}