{"?xml":{"@version":"1.0"},"edm:RDF":{"@xmlns:dc":"http://purl.org/dc/elements/1.1/","@xmlns:edm":"http://www.europeana.eu/schemas/edm/","@xmlns:wgs84_pos":"http://www.w3.org/2003/01/geo/wgs84_pos","@xmlns:foaf":"http://xmlns.com/foaf/0.1/","@xmlns:rdaGr2":"http://rdvocab.info/ElementsGr2","@xmlns:oai":"http://www.openarchives.org/OAI/2.0/","@xmlns:owl":"http://www.w3.org/2002/07/owl#","@xmlns:rdf":"http://www.w3.org/1999/02/22-rdf-syntax-ns#","@xmlns:ore":"http://www.openarchives.org/ore/terms/","@xmlns:skos":"http://www.w3.org/2004/02/skos/core#","@xmlns:dcterms":"http://purl.org/dc/terms/","edm:WebResource":[{"@rdf:about":"http://www.dlib.si/stream/URN:NBN:SI:DOC-HM57HRNU/54b3d235-2c59-4186-bf95-3c61a02a1ab7/PDF","dcterms:extent":"2157 KB"},{"@rdf:about":"http://www.dlib.si/stream/URN:NBN:SI:DOC-HM57HRNU/da94b17d-fbc2-4467-b12d-1d8ca64e04f2/TEXT","dcterms:extent":"0 KB"}],"edm:TimeSpan":{"@rdf:about":"2013-2025","edm:begin":{"@xml:lang":"en","#text":"2013"},"edm:end":{"@xml:lang":"en","#text":"2025"}},"edm:ProvidedCHO":{"@rdf:about":"URN:NBN:SI:DOC-HM57HRNU","dcterms:isPartOf":[{"@rdf:resource":"https://www.dlib.si/details/URN:NBN:SI:SPR-XAYCFMST"},{"@xml:lang":"sl","#text":"Journal of energy technology"}],"dcterms:issued":"2024","dc:creator":["Glavaš, Hrvoje","Marković, Monika","Strilić, Antonija"],"dc:format":[{"@xml:lang":"sl","#text":"številka:aug. 2024"},{"@xml:lang":"sl","#text":"letnik:iss. 2"},{"@xml:lang":"sl","#text":"str. 11-21"}],"dc:identifier":["ISSN:1855-5748","COBISSID_HOST:205900803","URN:URN:NBN:SI:doc-HM57HRNU"],"dc:language":"en","dc:publisher":{"@xml:lang":"sl","#text":"Fakulteta za energetiko"},"dc:subject":[{"@xml:lang":"en","#text":"electrical energy"},{"@xml:lang":"sl","#text":"električna energija"},{"@xml:lang":"en","#text":"plant"},{"@xml:lang":"sl","#text":"rastlina"},{"@xml:lang":"sl","#text":"termografija"},{"@xml:lang":"en","#text":"thermography"},{"@xml:lang":"en","#text":"UHI"},{"@xml:lang":"sl","#text":"vodni stres"},{"@xml:lang":"en","#text":"water stress"}],"dcterms:temporal":{"@rdf:resource":"2013-2025"},"dc:title":{"@xml:lang":"sl","#text":"Infrared thermography in the detection of water stress in plants| Infrardeča termografija pri odkrivanju vodnega stresa v rastlinah|"},"dc:description":[{"@xml:lang":"sl","#text":"Plants and green islands in urban areas are one way to mitigate climate change and reduce the energy demand for air conditioning. Like humans, plants are also exposed to the urban heat island effect, which manifests itself in the fact that air temperatures in urban areas are on average 2-5°C higher than in rural areas. In addition, plants are exposed to water stress, which occurs when the amount of available water exceeds or falls short of the plants' water requirements. The paper presents an increase in electricity demand, with a special focus on Croatia, Slovenia and countries with similar electricity consumption. The effects of the urban heat island are illustrated using a graphical comparison from the recent literature. Infrared thermography, as one of the methods for detecting water stress, is explained with the physical background of long-wave radiation detection, and compared with near infrared digital photography. All possible aspects are presented of radiation detection that occur during thermographic analysis. A specific overview of water stress is given, and its effects are illustrated using examples of plant height and flower size. The application of infrared thermography in the detection of water stress is illustrated using thermograms of wheat in a dry field and after irrigation. On the basis of the presented information, a conclusion was drawn about the possibility of using infrared thermography in the detection of water stress"},{"@xml:lang":"sl","#text":"Rastline in zeleni otoki v urbanih območjih so eden od načinov za ublažitev podnebnih sprememb in zmanjšanje povpraševanja po energiji za klimatske naprave. Tako kot ljudje so tudi rastline izpostavljene učinku mestnega toplotnega otoka, ki se kaže v tem, da so temperature zraka v urbanih območjih v povprečju za 2?5 °C višje kot na podeželju. Poleg tega so rastline izpostavljene vodnemu stresu, ki nastane, ko količina razpoložljive vode presega ali pade pod potrebe rastlin po vodi. Prispevek prikazuje porast povpraševanja po električni energiji s posebnim poudarkom na Hrvaški, Sloveniji in državah s podobno porabo električne energije. Učinki mestnega toplotnega otoka so prikazani z grafično primerjavo iz novejše literature. Infrardeča termografija kot ena od metod za zaznavanje vodnega stresa je pojasnjena s fizikalnim ozadjem zaznavanja dolgovalovnega sevanja in primerjana z digitalno fotografijo blizu infrardečega sevanja. Predstavljeni so vsi možni vidiki detekcije sevanja, ki nastanejo pri termografski analizi. Podan je poseben pregled pomanjkanja vode, njegovi učinki pa so prikazani na primerih višine rastline in velikosti cvetov. Uporaba infrardeče termografije pri zaznavanju pomanjkanja vode je prikazana s termogrami pšenice na suhem polju in po namakanju. Na podlagi predstavljenega so sklepali o možnostih uporabe infrardeče termografije pri detekciji vodnega stresa"}],"edm:type":"TEXT","dc:type":[{"@xml:lang":"sl","#text":"znanstveno časopisje"},{"@xml:lang":"en","#text":"journals"},{"@rdf:resource":"http://www.wikidata.org/entity/Q361785"}]},"ore:Aggregation":{"@rdf:about":"http://www.dlib.si/?URN=URN:NBN:SI:DOC-HM57HRNU","edm:aggregatedCHO":{"@rdf:resource":"URN:NBN:SI:DOC-HM57HRNU"},"edm:isShownBy":{"@rdf:resource":"http://www.dlib.si/stream/URN:NBN:SI:DOC-HM57HRNU/54b3d235-2c59-4186-bf95-3c61a02a1ab7/PDF"},"edm:rights":{"@rdf:resource":"http://rightsstatements.org/vocab/InC/1.0/"},"edm:provider":"Slovenian National E-content Aggregator","edm:intermediateProvider":{"@xml:lang":"en","#text":"National and University Library of Slovenia"},"edm:dataProvider":{"@xml:lang":"sl","#text":"Univerza v Mariboru, Fakulteta za energetiko"},"edm:object":{"@rdf:resource":"http://www.dlib.si/streamdb/URN:NBN:SI:DOC-HM57HRNU/maxi/edm"},"edm:isShownAt":{"@rdf:resource":"http://www.dlib.si/details/URN:NBN:SI:DOC-HM57HRNU"}}}}