{"?xml":{"@version":"1.0"},"edm:RDF":{"@xmlns:dc":"http://purl.org/dc/elements/1.1/","@xmlns:edm":"http://www.europeana.eu/schemas/edm/","@xmlns:wgs84_pos":"http://www.w3.org/2003/01/geo/wgs84_pos","@xmlns:foaf":"http://xmlns.com/foaf/0.1/","@xmlns:rdaGr2":"http://rdvocab.info/ElementsGr2","@xmlns:oai":"http://www.openarchives.org/OAI/2.0/","@xmlns:owl":"http://www.w3.org/2002/07/owl#","@xmlns:rdf":"http://www.w3.org/1999/02/22-rdf-syntax-ns#","@xmlns:ore":"http://www.openarchives.org/ore/terms/","@xmlns:skos":"http://www.w3.org/2004/02/skos/core#","@xmlns:dcterms":"http://purl.org/dc/terms/","edm:WebResource":[{"@rdf:about":"http://www.dlib.si/stream/URN:NBN:SI:DOC-9J7S55GQ/08b42c31-f649-446b-8db5-3bc7559350b9/PDF","dcterms:extent":"494 KB"},{"@rdf:about":"http://www.dlib.si/stream/URN:NBN:SI:DOC-9J7S55GQ/97575b0e-bf58-466d-97a7-da5fddaf2ed8/TEXT","dcterms:extent":"21 KB"}],"edm:TimeSpan":{"@rdf:about":"2013-2025","edm:begin":{"@xml:lang":"en","#text":"2013"},"edm:end":{"@xml:lang":"en","#text":"2025"}},"edm:ProvidedCHO":{"@rdf:about":"URN:NBN:SI:DOC-9J7S55GQ","dcterms:isPartOf":[{"@rdf:resource":"https://www.dlib.si/details/URN:NBN:SI:SPR-XAYCFMST"},{"@xml:lang":"sl","#text":"JET on-line"},{"@xml:lang":"sl","#text":"Journal of energy technology"}],"dcterms:issued":"2017","dc:creator":["Bušić, Josip","Topić, Danijel","Žnidarec, Matej"],"dc:format":[{"@xml:lang":"sl","#text":"letnik:10"},{"@xml:lang":"sl","#text":"številka:iss. 1"},{"@xml:lang":"sl","#text":"str. 47-58"}],"dc:identifier":["COBISSID:1024271964","ISSN:1855-5748","URN:URN:NBN:SI:doc-9J7S55GQ"],"dc:language":"en","dc:publisher":{"@xml:lang":"sl","#text":"Fakulteta za energetiko"},"dc:subject":[{"@xml:lang":"en","#text":"efficiency"},{"@xml:lang":"sl","#text":"elektrarne"},{"@xml:lang":"sl","#text":"fotonapetostni sistemi"},{"@xml:lang":"sl","#text":"izgube"},{"@xml:lang":"en","#text":"power losses"},{"@xml:lang":"sl","#text":"senčenje"},{"@xml:lang":"en","#text":"shading"},{"@xml:lang":"en","#text":"thin-film PV module"}],"dcterms:temporal":{"@rdf:resource":"2013-2025"},"dc:title":{"@xml:lang":"sl","#text":"Influence of shading on I-V characteristics of thin film PV modules| Vpliv senčenja na I-U karakteristiko tankoplastnih fotonapetostnih modulov|"},"dc:description":[{"@xml:lang":"sl","#text":"Photovoltaic (PV) systems are, numerically, the most widespread type of power plant that harvests renewable energy sources for electricity production. This paper investigates the influence of shading on the electrical characteristics of thin-film PV modules. Two types of thin-film PV modules are used: amorphous silicon and copper-indium-selenide. The electrical parameters of PV modules under various cases of shading are measured, analysed, and presented in tables and charts. A comparison between the electrical characteristics of crystalline silicon and thin-film PV modules under shading showed that thin-film PV modules have more consistent electrical parameters. I-V and P-V characteristics of shape of thin-film PV module are unaffected by shading. The power losses and efficiency of shaded modules are decreasing in linear relation to the increasing shaded area of a PV module"},{"@xml:lang":"sl","#text":"Fotonapetostni sistemi so številčno najbolj razširjena vrsta elektrarn, ki izkorišča obnovljivi vir energije za proizvodnjo električne energije. Članek obravnava vpliv senčenja na električne lastnosti tankoplastnih fotonapetostnih modulov. Uporabljata se dve vrsti tankoplastnih fotonapetostnih modulov, in sicer iz amorfnega silicija in bakra-indija selenid. V članku se tako merijo in analizirajo električni parametri fotonapetostnih modulov v okviru različnih primerov senčenje. Rezultati so predstavljeni tabelarično in grafično. Primerjava med električnimi lastnostmi silicijevih in tankoplastnih fotonapetostnih modulov v skladu s senčenjem je pokazala, da imajo tankoplastnih fotonapetostni moduli bolj dosledne električne parametre. Senčenje ne vpliva na I-U in P-U karakteristike tankoplastnih modulov. Izgube in izplen v primeru senčenja modula se zmanjšuje linearno glede na vse večjo senčenje območja modula"}],"edm:type":"TEXT","dc:type":[{"@xml:lang":"sl","#text":"znanstveno časopisje"},{"@xml:lang":"en","#text":"journals"},{"@rdf:resource":"http://www.wikidata.org/entity/Q361785"}]},"ore:Aggregation":{"@rdf:about":"http://www.dlib.si/?URN=URN:NBN:SI:DOC-9J7S55GQ","edm:aggregatedCHO":{"@rdf:resource":"URN:NBN:SI:DOC-9J7S55GQ"},"edm:isShownBy":{"@rdf:resource":"http://www.dlib.si/stream/URN:NBN:SI:DOC-9J7S55GQ/08b42c31-f649-446b-8db5-3bc7559350b9/PDF"},"edm:rights":{"@rdf:resource":"http://rightsstatements.org/vocab/InC/1.0/"},"edm:provider":"Slovenian National E-content Aggregator","edm:intermediateProvider":{"@xml:lang":"en","#text":"National and University Library of Slovenia"},"edm:dataProvider":{"@xml:lang":"sl","#text":"Univerza v Mariboru, Fakulteta za energetiko"},"edm:object":{"@rdf:resource":"http://www.dlib.si/streamdb/URN:NBN:SI:DOC-9J7S55GQ/maxi/edm"},"edm:isShownAt":{"@rdf:resource":"http://www.dlib.si/details/URN:NBN:SI:DOC-9J7S55GQ"}}}}