<?xml version="1.0"?><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xmlns:wgs84_pos="http://www.w3.org/2003/01/geo/wgs84_pos" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:rdaGr2="http://rdvocab.info/ElementsGr2" xmlns:oai="http://www.openarchives.org/OAI/2.0/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:skos="http://www.w3.org/2004/02/skos/core#" xmlns:dcterms="http://purl.org/dc/terms/"><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:DOC-88N6DEX6/b5a03a1b-80da-4bf3-8ca7-0731f175021d/PDF"><dcterms:extent>1024 KB</dcterms:extent></edm:WebResource><edm:WebResource rdf:about="http://www.dlib.si/stream/URN:NBN:SI:DOC-88N6DEX6/78b88e92-45e4-425a-bab1-b6ddfd4d1a44/TEXT"><dcterms:extent>33 KB</dcterms:extent></edm:WebResource><edm:TimeSpan rdf:about="2000-2024"><edm:begin xml:lang="en">2000</edm:begin><edm:end xml:lang="en">2024</edm:end></edm:TimeSpan><edm:ProvidedCHO rdf:about="URN:NBN:SI:DOC-88N6DEX6"><dcterms:isPartOf rdf:resource="https://www.dlib.si/details/urn:nbn:si:spr-fzwbu7gu" /><dcterms:issued>2024</dcterms:issued><dc:creator>Alibegović, Armin</dc:creator><dc:creator>Cvetko, Erika</dc:creator><dc:creator>Laubry, Lucija Lucie</dc:creator><dc:creator>Pušnik, Luka</dc:creator><dc:creator>Serša, Igor</dc:creator><dc:creator>Snoj, Žiga</dc:creator><dc:creator>Umek, Nejc</dc:creator><dc:contributor>Umek, Nejc</dc:contributor><dc:format xml:lang="sl">letnik:43</dc:format><dc:format xml:lang="sl">številka:ahead of print</dc:format><dc:format xml:lang="sl">str. 203-210</dc:format><dc:identifier>DOI:10.5566/ias.3332</dc:identifier><dc:identifier>ISSN:1580-3139</dc:identifier><dc:identifier>COBISSID_HOST:214139907</dc:identifier><dc:identifier>URN:URN:NBN:SI:doc-88N6DEX6</dc:identifier><dc:language>en</dc:language><dc:publisher xml:lang="sl">Društvo za stereologijo in kvantitativno analizo slike, Medicinska fakulteta</dc:publisher><dcterms:isPartOf xml:lang="sl">Image analysis and stereology</dcterms:isPartOf><dc:subject xml:lang="sl">analiza slike</dc:subject><dc:subject xml:lang="en">diffusion tensor imaging</dc:subject><dc:subject xml:lang="sl">difuzijsko tenzorsko slikanje</dc:subject><dc:subject xml:lang="en">fractional anisotropy</dc:subject><dc:subject xml:lang="sl">frakcijska anizotropija</dc:subject><dc:subject xml:lang="en">image analysis</dc:subject><dc:subject xml:lang="sl">periferni živec</dc:subject><dc:subject xml:lang="en">perineural tissue</dc:subject><dc:subject xml:lang="sl">perinevralno tkivo</dc:subject><dc:subject xml:lang="en">peripheral nerve</dc:subject><dcterms:temporal rdf:resource="2000-2024" /><dc:title xml:lang="sl">Analysis-associated factors interfering with diffusion tensor indices of peripheral nerves|</dc:title><dc:description xml:lang="sl">Diffusion tensor imaging (DTI) enables a non-invasive assessment of tissue architecture based on water diffusion. Advancements in technology have expanded the application of DTI from the central nervous system to the peripheral nervous system. High-resolution magnetic resonance imaging (MRI) systems have further enhanced the visualization of nerve compartments. This study investigates the influence of region of interest (ROI) selection on DTI indices in ex vivoperipheral nerves. Cadaveric median nerves (n=10) were harvested and immersed in fluorinated-carbon liquid, and 9-mm segments were independently scanned with a 9.4-T MRI system (scanning time 40 h). Diffusion-weighted signals were summed, and diffusion tensors were calculated for anatomical compartments using different delineation techniques. Following the initial scan, five samples were scanned for the second time using an identical protocol. The analysis showed that the inclusion of an inert background into the ROI significantly reduces fractional anisotropy (FA). Significant differences in diffusion tensors were observed between the initial and intermediate nerve portions, with FA and mean diffusivity (MD) differing by as much as 25.2% and 25.6%, respectively. Tracing the fascicles without the interfascicular epineurium exhibited an 8.8% lower FA compared to the delineations of the epineurium. Second MRI scans showed significant changes in diffusion tensors with higher eigenvalues D1-D3 and MD. In conclusion, the intermediate portions of the nerve demonstrated greater consistency in DTI indices and are therefore recommended for analysis over the initial portions. Using an inert liquid can minimize background effects, but the inherent diffusion properties of the tissue must be carefully considered. Prolonged scanning times can alter diffusion tensors, likely due to autolytic processes, underscoring the importance of consistent pre-scanning conditions and acquisition protocols. Additionally, maintaining consistency in delineations is paramount, regardless of whether the tracing method includes or excludes the interfascicular epineurium</dc:description><edm:type>TEXT</edm:type><dc:type xml:lang="sl">znanstveno časopisje</dc:type><dc:type xml:lang="en">journals</dc:type><dc:type rdf:resource="http://www.wikidata.org/entity/Q361785" /></edm:ProvidedCHO><ore:Aggregation rdf:about="http://www.dlib.si/?URN=URN:NBN:SI:DOC-88N6DEX6"><edm:aggregatedCHO rdf:resource="URN:NBN:SI:DOC-88N6DEX6" /><edm:isShownBy rdf:resource="http://www.dlib.si/stream/URN:NBN:SI:DOC-88N6DEX6/b5a03a1b-80da-4bf3-8ca7-0731f175021d/PDF" /><edm:rights rdf:resource="http://creativecommons.org/licenses/by/4.0/" /><edm:provider>Slovenian National E-content Aggregator</edm:provider><edm:intermediateProvider xml:lang="en">National and University Library of Slovenia</edm:intermediateProvider><edm:dataProvider xml:lang="sl">Društvo za stereologijo in kvantitativno analizo slike</edm:dataProvider><edm:object rdf:resource="http://www.dlib.si/streamdb/URN:NBN:SI:DOC-88N6DEX6/maxi/edm" /><edm:isShownAt rdf:resource="http://www.dlib.si/details/URN:NBN:SI:DOC-88N6DEX6" /></ore:Aggregation></rdf:RDF>