Acta Chim. Slov. 2004, 51, 33-38. 33 Scientific Paper HIGH-RESOLUTION X-RAY ABSORPTION SPECTROMETRY OF ATOMIC VAPORS Andrej Mihelič,a Alojz Kodre, Iztok Arčon,cand Jana Padežnik Gomilšek a " / r Jozej Stejan Institute, Jamova 39, 1000 Ljubljana b T7 f+l r>7 taculty oj Matnematics and rnysics, Jadranska 19, 1000 Ljubljana Jožef Štefan Institute, Jamova 39, 1000 Ljubljana C /-> d j tz C r^ Nova uorica rolytecnnic, vipavska 13, j000 Nova uorica Jožef Štefan Institute, Jamova 39, 1000 Ljubljana dr? f 7 77 1 taculty oj Mecnanical Lngineering, Smetanova 1/, 2000 Maribor Received 17-10-2003 Abstract A measurement of an x-ray absorption spectrum of a monatomic sample yields pure atomic absorption essential for the EXAFS (Extended X-ray Absorption Fine Structure) analysis in cases of a weak structural signal. A construction of an absorption celi to contain vapor sample takes into account specific properties of the investigated element. Metal-vapor absorption cells for the elements K, Zn, Rb, Cd, Cs, and Hg are presented and comments are made on the use of materials and the operating mechanisms of the cells. Key words: x-ray absorption, atomic vapors, K, Zn, Rb, Cd, Cs, EXAFS Introduction X-ray absorption spectroscopy is a powerful spectroscopic technique that owes its popularity among physicists and chemists mainly to its relative simplicity and, especially in the last decades, to availability of synchrotron light sources, where spectra with high energy resolution and signal to noise ratio of the order 10 are attainable. In x-ray absorption spectra of bound atoms, the absorption coefficient changes in an oscillatory fashion with the energy of incident photons inside the region extending to about 1 keV above an absorption edge. These oscillations - the extended x-ray absorption fine structure (EXAFS) - arise from scattering of the ejected photoelectron on atoms surrounding the photoionised atom. EXAFS signal contains information about the arrangement and atomic species of the surrounding atoms and is used in structural analysis of materials. The method is most useful for structural analysis of compounds without long-range order where XRD (X-ray diffraction) methods cannot be used. A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek: High-Resolution x-ray Absorption Spectrometry... 34 Acta Chim. Slov. 2004, 51, 33-38. 1.2 0.8 0.4 0.0 15.15 15.20 15.25 15.30 15.35 15.40 E (keV) Figure 1. The normalised K-shell X-ray absorption spectra of atomic rubidium (top) and RbN03 solution (bottom). The vapor spectrum is shifted along the y-axis for clarity. The spectrum in the energy region above an absorption edge contains, in addition to EXAFS oscillations in the čase of bound atoms, sharp spectral features - fingerprints of collective moti on of electrons inside the atom (Figure 1). These sharp features are produced by multielectron photoexcitations (MPE), i.e., the processes where - beside the photoexcitation of the inner shell of the atom - one or more additional electrons are ejected to continuum or to unoccupied bound states. In materials with weak EXAFS oscillations, the MPE and the EXAFS signals can be comparable in magnitude, so that the EXAFS structural analysis can be seriously hampered without prior knowledge of the MPE signal. Absorption spectra of monatomic samples exhibit no EXAFS oscillations, whereas they do contain the MPE signal. A straightforvvard way of obtaining an approximation for the MPE in the spectra of bound atoms is therefore to measure the A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek: High-Resolution x-ray Absorption Spectrometry... Rb vapor Acta Chim. Slov. 2004, 51, 33-38. 35 absorption spectra in monatomic vapors of these elements. Readily amenable to atomic measurements are noble gases, but with some experimental effort, experiments with other elements which form monatomic vapors can also be prepared. Apart from noble gases, " atomic absorption has been measured only on some metals, " among which we measured for the first tirne atomic absorption spectra of the most volatile metals Rb, K, Zn, Cs, and Cd, and remeasured Hg. The experiments were performed at three European beamlines: XI and E4 of Hasvlab, DESY (Rb/Cs and K, respectivelv), and BM29 of ESRF, Grenoble (Zn, Cd and Hg). For high quality x-ray absorption spectra a sample density of the order of 10 mg/cm is required. Ionic and atomic beams, used in the visible and the UV spectral regions, do not provide enough density and are therefore inadequate. Dense metal vapors are contained in absorption cells with low-absorption windows. Materials used for the cells and the windows, which represent the most delicate part of the celi, must withstand the aggressive vapor and the high temperatures needed to vaporise the metals. The windows must be thin enough to transmit the incident beam sufficiently and yet withstand some pressure difference. The investigated elements differ in chemical reactivity and in the energy of their x-ray absorption edges, i.e., their penetration; the choice of materials is therefore specific to each of the elements. Cadmium (BP 765 °C) and mercury (BP 357 °C) absorption spectra were measured in simple sealed quartz cells. As the energies of Cd K edge (26711 eV) and Hg L edges (14839, 14209, and 12284 eV) are rather high, 1 mm and 0.25 mm thick quartz windows, respectively, provided sufficient transmission. Prior to sealing, the cells with the samples were introduced and the cells were evacuated to 10" mbar. The Cd and Hg cells were heated using a tubular oven to 950 °C and 340 °C, respectively, producing vapor pressures of 168 kPa in the Cd celi and 28 kPa in the Hg celi. The working temperature was chosen just high enough to evaporate the sample entirely to assure that the vapor density remained constant throughout the experiment. Rb and Cs both combine with quartz at the boiling points of the both elements (679 °C and 690 °C, respectively). For this reason, sealed stainless steel cells with thin stainless-steel windows (0.01 mm) were used (Figure 2). Vacuum tightness of the cells was tested with a helium leak detector. The metals evaporated completely at 690 °C (Rb) and 610 °C (Cs), yielding vapor pressures of 71 kPa and 34 kPa, respectively. A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek: High-Resolution x-ray Absorption Spectrometry... 36 Acta Chim. Slov. 2004, 51, 33-38. Figure 2. Top: side view of the stainless-steel absorption celi for rubidium and cesium vapor: 1 - tube, 2 - windows, 3 - sample. Bottom: the celi after the experiment. Due to the low energy of potassium K edge (3608 eV) and the consequently high absorption of the x-ray beam in the windows, the only admissible materials for the windows are organic foils, e.g., kapton. Organic materials have to be protected from the hot and aggressive vapor (BP 774 °C). This is achieved by the use of a spectroscopic heat-pipe depicted in Figure 3. A steady circulation of vapor is established by heating the central part of the stainless steel tube and water-cooling its outer parts. Shielding of the windows is provided by a layer of an inert gas, coming from a reservoir through gas inlets. The celi was filled with approximately 3 g of potassium. A vapor pressure of 53 kPa was established at approximately 700 °C. A two-hour stable operation rendered the absorption spectrum of the vicinity of the potassium K edge. 2 r 4 5 Figure 3. Heat pipe celi for potassium vapor. Top: a schematic view (1 - stainless steel tube, 2 - oven, 3 - water container, 4 - gas inlet, 5 - kapton windows). Bottom: the middle part of the device; the ends with gas inlets are not shown. 3 A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek: High-Resolution x-ray Absorption Spectrometry... Acta Chim. Slov. 2004, 51, 33-38. 37 Zine in vapor (BP 907 °C) is known to combine with quartz and stainless steel, the two materials most commonly used in vacuum engineering, so we tried a corundum celi with 0.125 mm corundum windows attached with a high-temperature zirconia cement (Figure 4, top). The celi was not vacuum-tight; the zine vapors escaped slowly. Consequently, the bateh of zine exceeded the quantity for the static (i.e., sealed-cell) filling to sustain a stable vapor pressure. Inert atmosphere was provided to prevent oxidation of the zine vapor by inserting the corundum celi into a larger quartz tube with aluminium windows. Baffles were inserted at both ends of the tube to suppress conveetion and prevent zine vapor to reach the aluminium windows. The corundum celi and the quartz tube were heated to 750 °C using the tubular oven; the absorption thickness of the sample corresponded to a vapor pressure of approximately 21 kPa. 4 1 2 Figure 4. Top: the absorption celi for zine vapor: 1 - corundum celi, 2 - alumina window, 3 - quartz tube, 4 - aluminium window, 5 - baffle, 6 - oven. Bottom: the celi after the experiment. Acknowledgements Support of Slovenian Ministry of Education, Science and Šport, and Internationales Biiro des BMBF (Germany) is acknowledged. The synchrotron radiation experiments at the ESRF were performed under proposals No. HE-375, No. CH-1298 A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek: High-Resolution x-ray Absorption Spectrometry... 38 Acta Chim. Slov. 2004, 51, 33-38. and No. HE-1522; expert advice on BM29 beamline operation was provided by A. Filipponi and M. Borowski. The experiment at HASYLAB at DESY was performed at the beamlines E4 and X1 under proposal II-98-043. M. Tischer of HASYLAB provided expert advice on beamline operation. References 1. J. J. Rehr, R. C. Albers, Rev. Mod. Phys. 2000, 72, 621-654. 2. S. J. Schaphorst, A. Kodre, J. Ruscheinski, B. Crasemann, T. Aberg, J. Tulkki, M. H. Chen, Y. Azuma, G. S. Brown, Phys. Rev. A 1993, 47, 1953-1966. 3. J. M. Esteva, B. Gauthé, P. Dhez, R. C. Karnatak, J. Phys. B 1983, 16, L263-L268. 4. M. Deutsch, M. Hart, Phys. Rev. Lett. 1986, 57, 1566-1569. 5. I. Arčon, A. Kodre, M Štuhec, D. Glavič-Cindro, W. Drube, Phys. Rev. A 1995, 51, 147-154. 6. R. Bruhn, B. Sonntag, H. W. Wolff, J. Phys. B 1979, 12, 203-212. 7. G. Materlik, B. Sonntag, M. Tausch, Phys. Rev. Lett. 1983, 51, 1300-1303. 8. O. Keski-Rahkonen, G. Materlik, B. Sonntag, J. Tulkki, J. Phys. B 1984, 17, L121-L126. 9. A. Filipponi, L. Ottaviano, T. A. Tyson, Phys. Rev. A 1993, 48, 2098-2101. 10. U. Arp, B. M. Lagutin, G. Materlik, I. D. Petrov, B. Sonntag, V. L. Sukhorukov, J. Phys. B 1993, 26, 4381-4398. 11. R. Prešeren, I. Arčon, M. Mozetič, A. Kodre, A. Pregelj, Nucl. Instr. and Meth. B 1996, 111, 161-162. 12. R. Prešeren, A. Kodre, I. Arčon, J. Padežnik Gomilšek, M. Hribar, Nucl. Instr. and Meth. B 1999, 149, 238-240. 13. A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek, M. Borowski, Nucl. Instr. and Meth. B 2002, 196, 194-197. 14. J. Padežnik Gomilšek, A. Kodre, I. Arčon, M. Hribar, Phys. Rev. A 2003, 68, 042505. 15. A. Kodre, I. Arčon, J. Padežnik Gomilšek, A. Mihelič, ESRF experimental report 2003, experiment number: HE-1522. Povzetek Z meritvijo rentgenskega absorpcijskega spektra enoatomnega vzorca dobimo atomsko absorpcijo, ki je nujna za analizo EXAFS (Extended X-ray Absorption Fine Structure -podaljšana drobna struktura rentgenskih absorpcijskih robov), kadar je strukturni signal šibek. Izdelava absorpcijske celice, v kateri hranimo uparjeni vzorec, je odvisna od lastnosti preiskovanega elementa. V prispevku so predstavljene absorpcijske celice za kovinske pare K, Zn, Cd, Rb, Cs in Hg, posebna pozornost pa je namenjena delovanju celic in materialom, ki so bili uporabljeni pri njihovi izdelavi. A. Mihelič, A. Kodre, I. Arčon, J. Padežnik Gomilšek: High-Resolution x-ray Absorption Spectrometry...