prediction of the pile behaviour under dynamic loading using embedded strain sensor technology ANDREJ ŠTRUKELJ, MIRKO PŠUNDER, HELENA VRECL-KOJC and LUDVIK TRAUNER About the authors Andrej Štrukelj University of Maribor Faculty for Civil Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia e-mail: andrej.strakelj@uni-mb.si Mirko Pšunder University of Maribor Faculty for Civil Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia e-mail: mirko.psunder@uni-mb.si Helena Vrecl-Kojc University of Maribor Faculty for Civil Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia e-mail: helena.vrecl@uni-mb.si Corresponding author Ludvik Trauner University of Maribor Faculty for Civil Engineering, Smetanova ulica 17, 2000 Maribor, Slovenia e-mail: trauner@uni-mb.si Abstract A standard dynamic loading test of the pile was performed on the highway section Slivnica - Hajdina near Maribor, Slovenia. Parallel to standard testing procedures the new monitoring technology based on specially developed strain sensors installed inside the pile body along the pile axis was introduced. On the basis of the measured results the normal strains along the pile axis were measured. Taking into consideration the elastic modulus of the concrete the normal stresses in the axial direction of the pile were also calculated and afterwards the shear stresses along the pile shaft have been estimated as well as the normal stresses below the pile toe. The estimation was made by considering a constant value for the pile diameter. The measured results were also compared with the computer simulation of the pile and the soil behaviour during all the successive test phases. The strain measurements inside the pile body during the standard dynamic loading test in present case did not have the purpose of developing an alternative method of pile loading tests. It gave in the first place the possibility of a closer look at the strains and stresses of the most unapproachable parts of different types of concrete structure elements especially piles and other types of deep foundations. The presented monitoring technology proved itself as a very accurate and consistent. Keywords piles, deep foundations, dynamic loading test, strain measurement technologies, elasto-plastic modelling, finite-elements method 1 introduction The bearing capacity and settlement of vertical loaded pile can be estimated using different methods [2, 6]. In order to identify the pile behaviour and its interaction with the surrounding soil layers, knowledge of the state of the strains along the pile axis inside the pile body is of essential importance. To make this possible, a chain of measurement points has to be included outside the pile structure and it should be fixed to the appropriate position on the pile reinforcement before the reinforcement is placed in the pile pit. After that the standard procedure for concreting the pile must be executed. The first opportunity for testing this idea was an estimation of the testing pile shaft's resistance, as described in the paper Štrukelj et. al. [8]. The basis of this estimation was the measurement of the normal strains of the pile in its axial direction at measuring points distributed over equal distances along the pile axis. These strains are proportional to the axial forces in the pile. When the course of the axial force along the pile axis is known, the resistance of the pile shaft can be estimated. The measurement points were distributed over equal distances of 1.0 m, starting 0.5 m above the pile toe. Since the strain gauges, electrical contacts and communication cables are very sensitive, any moisture ACTA GEOTECHNICA SLOVENICA, 2009/1 51. A. STRUKEL! ET AL.: PREDICTION OF THE PILE BEHAVIOUR UNDER DYNAMIC LOADING USING EMBEDDED STRAIN SENSOR TECHNOLOGY and mechanical loading could be very harmful to their performance. Therefore, the measuring points were protected with special care. To ensure the mechanical protection of the chain of strain gauges together with the communication cables the whole measuring system was built inside a steel tube made of two standard C-profiles. The interior surface of the steel tube also served as the grounding surface to which the strain gages could be glued. For transportation reasons the tube was made of three segments that could be easily put together. The mutual connection of the segments was ensured by a special system of joints. The tubes external surface was degreased and made rough to ensure the adhesion with the concrete. Each strain gauge inside the tube was protected against the moisture. When the measuring tube was finished, it was connected with the pile reinforcement and put into the pit that was prepared for the pile concreting. The measurement system fulfilled the expectations and the measured results were accurate and stable. The only disadvantage of this measurement system was its non-flexibility. It could only be used to build the measurement chains where the measurement points are placed along one line and oriented in the same direction. The loading test included seven loading cases. Each represented the drop of a steel weight from a different height to the top of the test pile and the second and third hits after the first and second repulsions [9]. The location of the testing pile was selected on a construction site of the highway section Slivnica -Hajdina in Slovenia. The geological conditions of the testing pile's location and the positions of the nine sensors are shown in Fig.1, and described in Section 2.1. In the following sections the measuring equipment, its installation, the performance of dynamic loading test, and finally the evaluation of the measurement results is presented. In the last part of the paper the comparison of the measured results with results of numerical axis-symmetry analyses using the finite-element method (FEM) is presented. 2 preliminary works on the testing site 2.1 geological field and laboratory investigations Geological conditions of the wider location of the testing site were acquired from the geotechnical report for the design of a highway crossover foundation [7]. The strength and deformability parameters were defined on the basis of field investigations by a standard penetra- tion test and probe measurements, as well as by laboratory testing of the samples taken by sounds of depth up to 25 m from seven different locations. The region belongs to the eastern part of the River Drava field that is mainly a plain area with only small differences in height. The relief evolution is based on the accumulation river-denudation with river influences in the past, which have deposited a layer, more than 10 m thick, of gravel GP, sandy gravel GP-GM, and some lenses of sandy clay CL with boulders over the Miocene base of sandy marl. On the location of the testing pile one additional sounding to the depth of 15.0 m was performed. The strength and deformability parameters at some depths of this additional sound were defined on the basis of field investigations by standard dynamic penetration tests, and also on the basis of the laboratory testing of samples. The ground water level in this sounding was encountered at approximately 3.30 m below the surface. The cross-section of the ground space with the pile (Fig. 1.) is composed of a thin, 1.0 m layer of embankment that was built on an original space of eight characteristic layers of different thicknesses. Fig. 1 shows the geological conditions of the testing pile's location and the positions of the nine sensors. Table 1 presents the strength parameters and the classification (0 is the internal friction of the soil, c is the cohesion of the soil, and Eoed is the oedometer elasticity modulus of the soil) of the layers presented in Fig. 1, which were determined on the basis of laboratory and field testing on additional sound samples. 2.2 measuring equipment Besides the standard equipment that is needed for an estimation of the bearing capacity of the pile on the basis of a dynamical loading test [1], the additional specially produced strain sensors were built into the pile body. They were placed at equal distances of 2.0 m along the pile axis, starting at 1.5 m from the pile toe. The patented sensor design used for this purpose is very efficient, easy to build in, and robust enough to stand the water pressure and all the possible mechanical burdens during the pile concreting. The final solution for the strain sensor was to build a complete strain sensor for a single measurement point for all the layers of protection coatings and wiring. Such a sensor can be placed in the desired position in a very short time. It is insensitive to moisture and dust and its vital parts are very well protected against mechanical damage. The basis for such a sensor is a standard reinforcement bar of length about 150 cm and diameter 16 mm. In the ACTA GeOTeCHNICA SLOVENICA, 2009/1 JJ. A. STRUKEL! ET AL.: PREDICTION OF THE PILE BEHAVIOUR UNDER DYNAMIC LOADING USING EMBEDDED STRAIN SENSOR TECHNOLOGY falling height 1.0-3.0m ▼ 3.30 o csj I loading equipment pile head _ embankment CL with ^ (SG-9 lenses ML o csj o csi o csi o