Strojniški vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 © 2016 Journal of Mechanical Engineering. All rights reserved. D0l:10.5545/sv-jme.2015.3339 Original Scientific Paper Received for review: 2015-12-26 Received revised form: 2016-03-03 Accepted for publication: 2016-03-21 Study on the Performance and Control of a Piezo-Actuated Nozzle-Flapper Valve with an Isothermal Chamber Mohammadreza Kamali1* - Seyed Ali Jazayeri1 -Farid Najafi2 - Kenji Kawashima3- Toshiharu Kagawa4 1 K. N. Toosi University of Technology, Faculty of Mechanical Engineering, Iran 2 University of Guilan, Engineering Faculty, Iran 3 Tokyo Medical and Dental University, Institute of Biomaterials and Bioengineering, Japan 4 Tokyo Institute of Technology, Japan A new integrated nozzle-flapper valve equipped with a piezoelectric actuator and an isothermal chamber has been developed and studied in detail. The designed single stage valve controls the pressure and flow rate simply, effectively, and separately. This idea can easily be used in the pilot stage of a two-stage valve as well. Application of isothermal condition in the valve load chamber eliminates the dynamic malfunction that may persist from temperature variation within the valve load chamber; consequently, the governing equations for the prediction of pressure dynamics in the chamber are much more accurate and simpler. The valve has been equipped with a stacked type piezoelectric actuator which has a unique behaviour. Furthermore, stiffness, in the selected actuator, is enhanced against the thrust of the discharging flow from the nozzle, thus decreasing the complexity of dynamic equations of the valve. A detail mathematical model and simulation was developed to study the dynamic performance analysis of the proposed valve. An experimental test rig was built to validate the results of simulations. The unique features and performance of the proposed valve were studied thoroughly. The valve's governing equations are nonlinear in nature, and some variables of the equations are a source of some uncertainties; sliding mode approach was used to control the steady and unsteady pressure and output flow rate of the valve. Keywords: nozzle-flapper (NF) valve, isothermal chamber, piezoelectric actuator, sliding mode approach Highlights • A new nozzle-flapper valve was designed and manufactured. • Its dynamics were improved using an isothermal chamber • A stacked piezoelectric actuator was utilized to actuate the proposed valve. • A sliding mode approach was used to precisely control the output flow rate or pressure. 0 INTRODUCTION Pneumatic actuation systems have been extensively utilized in high technology and complex industries, such as the semiconductor manufacturing process, for precise positioning to isolate vibration. A key element in the pneumatic control system is electro-pneumatic valve which not only converts the electrical signal to pneumatic one but also constructs a close-loop for control system; therefore, its structure and parameters play an important role to reach a necessary performance. Many research works have been conducted to increase the efficiency of pneumatic control systems through improved design and development of pneumatic valves with a new structure and improved dynamic characteristics. A new pneumatic valve that benefits from a piezoelectric actuator was developed to increase dynamic properties and reduce energy consumption [1]. In [2] a pneumatic positioner with a piezoelectric actuator was modeled, and its advantages were introduced. A pneumatic servo valve driven by a piezoelectric actuator with a simple amplification mechanism was presented in [3]. In contrast, some other research works have attempted to attain a reasonable and detailed mathematical model of the valve to optimize the control effort of the pneumatic system. Richer and Hurmuzlu [4] developed detailed mathematical models for each element of a pneumatic system to control the output of the actuator accurately. Wang et al. [5] made a new model for a nozzle-flapper (NF) valve to decrease the output thrust effect of the nozzle on the flapper. One of the effective structures in control valves is the NF mechanism, which can be used for obtaining quick response and precise control action due to its simple structure with high sensitivity and wide frequency range; many research works are being focused on studying and profiting from its advantages in the new structures of the fluid power valves. Kawashima et al. [6] designed and manufactured a new NF valve to minimize noise level and pressure fluctuations in the output flow of the valve. There have also been some research works that studied NF valves numerically to optimize their dimensional features [7] or suggested new structures to decrease detrimental effects of the output flow on it [8]. The load chamber is one of the main subdivisions of the NF valve, and its dynamics have an important role in the whole dynamic of the 318 *Corr. Author's Address: K.N.Toosi University of Technology , Vanak Sq., Tehran, Iran, mohammadrkamali@gmail.com Strajniski vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 valve. The lack of an accurate model for the state change of air in the load chamber of the NF valve makes the control of the system rather difficult. The state change model of the pressurized air in the load chamber is usually assumed as adiabatic or isothermal [9]. Realization of the isothermal condition in the load chamber makes the mathematical models of the NF valve simpler and improves its heat transfer criteria and dynamic characteristics. Therefore, implementing an isothermal condition in the load chamber of the valve facilitates its control. In other words, through only one pressure sensor, installed on the valve's load chamber, both pressure or flow rate can be controlled more easily [10]. Kawashima et al. [11] proposed a new method to measure the unsteady flow rate of pressurized air using an isothermal chamber. Using benefits of such a chamber, Kawashima et al. [12] presented a system to determine the characteristics of the pneumatic solenoid valves. In the following of [12], Wang et al. [13] developed the same system in a way that it was possible to determine the characteristics for electrically modulated pneumatic control valves using an isothermal chamber. Traditional NF valves use electromagnetic transducers to drive the flapper. However, this has shortcoming such as large dimensions, high electrical power consumption, slow response and susceptible to electromagnetic interference [3]. The most effective actuator that can overcome these limitations is a piezoelectric actuator. The unique properties of piezoelectric actuator make it the most appropriate choice for cases such as hazardous and sensitive industrial or medical environments. Piezoelectric actuators have much less electrical energy consumption along with much faster response time; also, the mechanism is spark- and magnetic-field free. These unique properties have made it much more applicable to be used as an actuator in pneumatic valves [1] to [3]. Furthermore, the stacked type of piezoelectric actuator simplifies the mathematical model of the valve due to its sturdy construction [5]. In this study, a detailed description of a new NF mechanism with isothermal load chamber and piezoelectric actuator is introduced. The proposed valve profits from both the isothermal load chamber and the piezoelectric actuator to simply, precisely, and effectively control the pressure or flow rate of the air without any concerns that may exist even in hazardous industrial environments. The theoretical analysis of the valve was developed to derive a more precise mathematical and simulation model. The static and dynamic performance of the proposed valve was assessed experimentally in order to validate the developed model and to highlight the advantages of the proposed valve. Due to the nonlinear behaviour of the proposed valve and existence of uncertainties in some variables of the valve's equations, sliding mode approaches have been designed and implemented to control the output flow rate and pressure of the proposed valve more precisely. Experimental data showed the effectiveness of the new NF valve; extended measurements were also carried out using steady and unsteady oscillatory output flow rate or pressure of the valve to prove its effectiveness. 1 PROPOSED VALVE 1.1 NF Mechanism A schematic drawing of the proposed NF system is shown in Fig. 1, which consists of two fixed flow restrictors ((a) and (f)), a nozzle (d), a load chamber (c), and a piezoelectric actuator set that moves a flapper (e). Pressure-regulated air is delivered to orifice (a) and the variable flow restrictor (d) connected in series. The variable flow restrictor is made possible by moving the flapper that changes the distance Xn between the nozzle head and the flapper. The flow rate through the nozzle and output orifice (f) is controlled by the distance between the flapper and nozzle. This would cause pressure changes of pb in the load chamber, which is usually referred as nozzle back-pressure. Fig. 1. Layout of the proposed NF system; (a) input orifice, (b) pressure sensor, (c) isothermal load chamber, (d) nozzle, (e) piezoelectric actuator and flapper, (f) output orifice To realize the isothermal condition in the load chamber (c) of the proposed valve, thin copper wires are inserted into the load chamber, which is specially designed and manufactured for the NF system [10]. Copper wires not only decrease the effective volume of the control chamber but also improve heat transfer conditions within the chamber. Copper wires absorb the heat generated during the compressing and filling process of air far more effectively. Several studies Study on the Performance and Control of a Piezo-Actuated Nozzle-Flapper Valve with an Isothermal Chamber 319 Strojniški vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 have proved the effectiveness of such systems in their research [10] to [13]. When pressurized air is ejected from the nozzle, flow force is exerted on the flapper. Wang et al. studied flow force effects on the moving flapper that improve the control performance, but dynamic analysis of a standard NF valve is far more complicated [5]. In proposed piezoelectric actuator, the flapper becomes sturdier by the flow forces so that there is no need to model its displacement in dynamic equations. 1.2 Piezoelectric Actuator Piezoelectric actuators convert electrical energy directly into mechanical energy. There are no moving parts to limit their resolution and mechanical performance. As shown in Fig. 2, there are two major types of piezoelectric actuator arrangements. These are either bending transducer or stacking transducer [14]. Fig. 2. Different piezoelectric actuators, stacked and bending transducer Figs. 3 and 4 illustrate a typical hysteresis characteristic of stacked and bending piezoelectric transducer, respectively. The rigidity of stacked piezoelectric actuator improves the hysteresis criteria and, due to lower deflection, the control pressure that is produced within the load chamber of NF mechanisms for the same supply pressure will be much higher. 10 20 30 40 50 60 Voltage [V] Fig. 3. Hysteresis behaviour of stacked type piezoelectric actuator Faster response is one of the main characteristic features of stacked type piezoelectric actuators. This characteristic is especially advantageous in actuating pneumatic valves. The stacked type piezoelectric actuator utilized in the proposed valve can reach its nominal displacement in approximately one third of the period at the resonant frequency, based on its specification in [15], which was also verified here. Fig. 4. Hysteresis behaviour of bending-type piezoelectric actuator The dynamic behaviour of a flapper equipped with a piezoelectric actuator, which has a very fast response, has a minor effect on the overall dynamic response of the NF mechanism; therefore, the dynamics of the flapper can be neglected. 1.3 Dynamic Model of an NF Mechanism with Isothermal Load Chamber Using state equation for pressurized air within the load chamber is shown in Fig. 1 Pb = Rßb V W, (1) where pb denotes the load chamber's absolute pressure, R is the gas constant, Qb is the load chamber temperature, W is mass of the air in the load chamber and V denotes the load chamber volume. Differentiating above equation with respect to time t: dpb R0h dW RW dt V dt V dt (2) Using continuity equation for air in the load chamber: dW dt = G1 - G2 - G3, (3) where, G is mass flow rate through orifices. Using above governing equations: dPb dt V V 1 2 3' V dt (4) 320 Kamali, M. - Jazayeri, S.A. - Najafi, F. - Kawashima, K. - Kagawa, T. Strajniski vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 Since during charge and discharge, the state of air in the load chamber is assumed to be isothermal, the above equation can be simplified: ^ = rÊl.(G1 - G2 - G3). dt V v 1 2 3' (5) For the isothermal chamber, the average temperature is assumed to be equal to the room temperature [10]. It is concluded from Eq. (5) that for a fixed chamber volume of V and the room temperature of db, an instantaneous desired mass flow rate G2 could be produced by controlling solely the pressure changes. The mass flow rate G is easily converted to volumetric flow rate Q under standard conditions: Q = G/p, (6) where p is pressurized air density. The compressed air flow rate through fixed or variable orifices could be either sonic or subsonic depending upon the upstream/downstream pressure ratio [16]. The mass flow rate through a restriction is a function of geometric parameters, the upstream and downstream pressures. Therefore, mass flow rates, Gb G2, and G3 are calculated as follows: ; if P2 < b G = C I293 PoCPiJ. 6i Pi if P > b (7) Pi where coefficient C is the sonic conductance, which represents the flow's passing ability, and is represented by C=Se / 5 where Se is effective area of orifices or nozzle and b is the critical pressure ratio. If G is calculated for input orifice then p1 = ps and p2 =pb, but if G is calculated for output orifice and nozzle then p1 =pb and p2 =pa. 1.4 Simulation Program as shown in Fig. 5 was constructed. Some experiments were carried out to determine the parameters of the developed model, which included the effective area coefficients of the orifices and nozzle, as well as the critical pressure ratio. Through comparison of simulation results and experimental data, the selected mentioned parameters are optimized. The effective area coefficients of the NF valve were chosen as 0.86 for input and output orifices and 1.0 for the variable orifice. The best critical pressure for designed structure is derived to be 0.53. Variable orifice Fig. 5. Simulation model for the proposed valve 1.5 Experimental Setup and Results An experimental test rig, shown in Fig. 6 for NF mechanism was designed and manufactured to validate the developed simulation model and prove the effectiveness of the proposed valve. Fig. 6. Developed NF mechanism layout A simulation model based on the above analysis is established and shown in Fig. 5. The input is the flapper displacement of Xn, while the outputs are the control pressure pb, and the flow rate Q. According to the reasoning mentioned earlier, the dynamic response of the piezoelectric actuator has a minor effect and is not taken into account. To validate the valve performance and developed model, a MATLAB/SIMULINK model of the system Table 1. Main parameters of the valve Symbol Description Value Doi Diameter of the input orifice 0.4 mm Doo Diameter of the output orifice 0.3 mm V Volume of the load chamber 0.7 cm3 Xn Displacement domain of the piezoelectric actuator 0 mm to 0.09 mm b Critical pressure ratio 0.53 321 Study on the Performance and Control of a Piezo-Actuated Nozzle-Flapper Valve with an Isothermal Chamber Strojniški vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 A pressure regulator was used to stabilize the air supply. Stabilized air is fed to the proposed valve through the input orifice. The dimensions of the main subdivisions of the proposed valve have been presented in Table 1. They were estimated using the simulation model before manufacturing the proposed valve and were estimated based on required output flow rate and dynamic behaviour. The load chamber of the valve was filled with copper wire of 50*10-3 cm diameter. Compact mass density was greater than 300 kgm-3. These circumstances fulfil the isothermal condition in the load chamber [10]. The utilized piezoelectric actuator in the proposed valve is specified with part number P-841.6 and is produced by Physik Instrumente. The control approach was developed and implemented in a MATLAB/SIMULINK environment. Digitally generated control signals using a MATLAB/Real-Time Workshop environment with a CSI-360116 data acquisition board (made by Interface) were used to drive the piezoelectric actuator through a power amplifier. A semi-conductive-type pressure sensor was used to measure the pressure of the isothermal chamber. The output flow rate is derived from Eq. (3) by differentiating the pressure; five sets of data were used for this purpose. A low-pass filter was used to smooth out the pressure curve. The cut-off frequency of the filter was 2.5 times greater than that of the input frequency. Tests were performed at a constant ambient temperature of 20 °C and supply air pressure of 400 kPa. 1.5.1 Results to Compare Isothermal and Conventional Settings Initially, some tests were carried out to show the effectiveness of the suggested isothermal chamber in comparison to the conventional chamber, which is a chamber without any metal wool for the setup, even though many previous studies had already shown its effectiveness [10] to [13]. The chamber volume was selected as 29.5 cm3. The isothermal chamber temperature fluctuation is shown in Fig. 7 for simulation results and experimental data. The input voltage to the piezoelectric actuator was [45 - 44.5 * sin(2f-i)] V. Using the stop method [11], the average temperature in the chamber was measured. The ambient temperature was 293 K in the test room. The frequency was 20 Hz. The experimental data are shown by dark points, and the solid line represents the simulation results. The temperature deviation is about 2 K, which suggests that isothermal condition by metal wool in the chamber is well established. Fig. 7. Temperature variation in the valve load chamber The step response of isothermal and conventional chambers is shown in Fig. 8. Initially, the distance between the flapper and head of the nozzle was at the upper limit and suddenly was reduced to zero. The response for isothermal chamber became faster due to both volume decrease and heat transfer effects. The pressure drop at the beginning of the figure in the isothermal case is due to utilization of copper wire in the load chamber. Fig. 8. Step response of both isothermal and conventional chambers In [11], for unsteady flow rate generation, the advantages of the isothermal chamber over the conventional chamber were well defined. According to the presented experimental data and simulation results, when the unsteady flow rate is generated by the pressure change with the conventional chamber, not only the gain but also the phase shows far larger errors, so it makes the control of the proposed valve more difficult; the control effort is also much higher. In the case of the isothermal chamber, the generated unsteady flow rate from the pressure change shows negligible error in the gain, and there is no phase delay. So the effectiveness of the isothermal chamber on the unsteady oscillatory flow generation is evident. 322 Kamali, M. - Jazayeri, S.A. - Najafi, F. - Kawashima, K. - Kagawa, T. Strajniski vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 1.5.2 Performance of the Proposed Valve For the proposed valve, the static behaviour of the simulation model and experimental data are shown in Fig. 9. The steady- state control pressure pb was plotted against the input displacement of the flapper Xn. Using the laser displacement measurement unit Acuity AR700-0125, Xn was measured precisely. Excellent agreement between simulation model and experimental data is observed despite some small differences which are thought to be due to the uncertainty in the volume of the load chamber and measurement of ambient temperature 0b. There is almost a linear relationship between the input displacement and steady state pressure of the load chamber when Xn varies within the small range of 0.018 mm to 0.075 mm displacement. Fig. 9. Static behaviour of the valve compared with simulation model Fig. 10. Step response of the proposed valve The dynamic response of the proposed valve is analysed using step and frequency responses. As illustrated in Fig. 10, the step response of the isothermal chamber for the proposed valve validates the mathematical model and simulation results. From Fig. 10, it can easily be concluded that there is no significant delay in pressure response of the proposed valve. The response time of the designed valve is about 2.5 ms, so the proposed valve can be classified as a fast switching valve. Therefore, it can be employed as a pilot stage for much bigger pneumatic valves. Fast response without any notable delay is a result of the utilization of piezoelectric actuator to actuate the valve, as was predicted in [2] and [3]. In this case, the maximum error between the simulation result and experimental data is only about 2 %. Another way to assess the compliance between the simulation model and experimental data is through sinusoidal inputs. When the flapper is excited to move in in a sinusoidal form, experimental data and simulation results are in good agreement at different frequencies. The experiments were performed for wide frequencies, ranging from 0.1 Hz to 100 Hz, and it is concluded that for all frequencies, simulation results and experimental data are in very good agreement. For a test result, mathematical models of the proposed valve have been linearized at one operating point, which is pb = 350 kPa at v = 65 V. The relevant valve transfer function is [10]: P (s)_ Kc v (s) Tcs +1' (8) where Tc is the time constant, and Kc is the proportional gain of the pressure response: T = V aR6„ (9) where a is the flow rate gain with respect to load chamber pressure. A sinusoidal input signal with amplitude voltage of 5 V and biased input voltage of 65 V was put to the valve at various frequencies. The frequency characteristics of the valve's pressure response were analysed with a Bode diagram as shown in Fig. 11. The bandwidth for the proposed valve with isothermal load chamber is about 50 Hz. Fig. 11. Frequency response of the proposed valve, magnitude is normalized by static gain Studying existing pneumatic control system having actuators with slow response (-20 Hz) reveals the importance of the proposed NF mechanism with suitable responses. Study on the Performance and Control of a Piezo-Actuated Nozzle-Flapper Valve with an Isothermal Chamber 323 Strojniški vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 2 DESIGN OF THE CONTROLLER FOR THE PROPOSED VALVE The governing equations of the designed valve are highly nonlinear and contain some parametric uncertainties. Use of nonlinear control criteria would give a far more precise control of the desired output flow rate or pressure. One of the well-known effective nonlinear robust control approaches is sliding mode control [17] and [18]. Primarily, a sliding mode controller was designed to control the output flow rate and pressure in the load chamber. The sliding mode control approach can be used to overcome the significant system nonlinearities initiated during pressure or flow rate control process in the presence of uncertainties. The proposed valve is considered as a single input-single output (SISO) nonlinear system, which can be easily described with the following state-space equation: P b = fX (Pb )-f2 (Pb )-f3 (Pb )• U (10) where f1, f and f are nonlinear mass flow rate functions through the input, output, and variable orifices, respectively. They are also results of product (R6a IV) in mass flow rate Eq. (7), for the orifices corresponding to f where i = 1, 2 and 3. Variable u is the control input denoted as the distance between nozzle head and flapper Xn. The main variables that contain uncertainties are volume of the control chamber V and its temperature 6a. The overestimated variation of the load chamber's volume is about ±5 %. Temperature fluctuation is about ±2 K. The upper and lower bounds of the functions fi are given by: fL. = f^ = R0„ 0.95V R0„ 1.05 V i = 1,2,3, i = 1,2,3. (11) (12) The control objective is designed to guarantee the state of pb to track a desired state of pbd in the presence of uncertainties. The relevant tracking error is introduced as follows: e = Pb - Pbd. (13) Furthermore, the sliding surface is described by [18]: 5 (e, t ) = d , — + 1 dt I e ■ dt, (14) where n is system order and A is a strictly positive constant that can be interpreted as the slope of the sliding surface in the phase plane. It can be seen that the integral of system error in the sliding surface (Eq. (14)) minimizes the reaching time. It is easy to show that this integral term will also increase the system order by one. Therefore, the system order for the proposed valve as pressure control is two. The sliding surface equation where n = 2 is given by: 5 (e, t ) = d , — + 1 dt I e ■ dt = e + lI e ■ dt, (15) time derivatives of the above equation lead to a linear error equation: S (e, t ) = e + Ae, (16) rearranging above equations: S (e, t ) = pb - pbd +Xe, (17) using Eq. (17) and Eq. (10), results in: s (e t ) = fx (Pb ) - f2 (Pb ) - f (Pb )u - pbd + he, (18) satisfying the sliding condition: 2 - - n is a positive constant, guaranteeing that the surface S will nonetheless be reached in a finite time smaller than S(t = 0) / n; see [18] for more details. The sliding mode control law is also well presented by: u = ueq + us (20) where ueq is the equivalent control signal that keeps the state within sliding surface and us is the switch function that compensates the state when leaving the sliding surface. The best estimation for ueq is obtained by setting S = 0 then from Eq. (18) ueq is derived: fx (Pb)-/2 (Pb)-/3 (Pb - Pbd = 0, (21) where f and f are unknown functions that are presented by upper and lower bounds and are easily estimated by fx and f2 which present the mean value of upper and lower bounds so: - (/1 " ?2 " Pbd +^e). (22) Error estimation of (/1 -f2) is considered to be bounded by function F(e, t): (e,t)>|(?! - J2 )-(; - f ) Furthermore, f3 is estimated as follows: (23) n-1 324 Kamali, M. - Jazayeri, S.A. - Najafi, F. - Kawashima, K. - Kagawa, T. Strajniski vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 f 3 ' A*' (24) taking a simple form for switching control input: (25) u = —K ■ Sat | S y is a strictly positive constant that is explained as a boundary layer thickness neighbouring the sliding surface which prevents chattering and Sat(s/y) is: Sat\S | =

thickness of boundary layer [m3 s-1 ] Fig. 19. Unsteady flow rate delivery (f = 25 Hz) Study on the Performance and Control of a Piezo-Actuated Nozzle-Flapper Valve with an Isothermal Chamber 327 Strojniški vestnik - Journal of Mechanical Engineering 62(2016)5, 318-328 6 REFERENCES [1] Herakovic, N., Noe, D. (2006). Analysis of the operation of pilot-stage piezo-actuator valves. Strojniški vestnik - Journal of Mechanical Engineering, vol. 52, no. 12, p. 835-851. [2] Huang, W., Zhao, Z., Zhao, Y., Qi, Q., Huang, Q. (2008). Dynamic characteristic research for piezo pneumatic intelligent valve positioner. 3rd IEEE Conference on Industrial Electronics and Applications, p. 665-669, DOI:10.1109/ICIEA.2008.4582598. [3] Zeng, H., Yuan, R.-B., Sun, C., Zhang, Z. (2012).Study on performance of laminated piezoelectric pneumatic servo valve. Procedia Engineering, vol. 31, p. 1140-1148, DOI:10.1016/j.proeng.2012.01.1154. [4] Richer, E., Hurmuzlu, Y. (2000). A high performance pneumatic force actuator system: Part I—nonlinear mathematical model. Journal of Dynamic Systems, Measurement, and Control, vol. 122, no. 3, p. 416-425, DOI:10.1115/1.1286336. [5] Wang, T., Cai, M., Kawashima, K., Kagawa, T. (2005). Modelling of a nozzle-flapper type pneumatic servo valve including the influence of flow force. International Journal of Fluid Power, vol. 6, no. 3, p. 33-43, DOI:10.1080/14399776.2005.107812 28. [6] Kawashima, K., Youn, C., Toshiharu, K. (2006). Development of a nozzle-flapper-type servo valve using a slit structure. Journal of Fluids Engineering, vol. 129, no. 5, p. 573-578, DOI:10.1115/1.2717617. [7] Peng, Z., Sun, C., Yuan, R., Zhang, P. (2012). The CFD analysis of main valve flow field and structural optimization for double-nozzle flapper servo valve. Procedia Engineering, vol. 31, p. 115-121, DOI:10.1016/j.proeng.2012.01.1000. [8] Aung, N.Z., Li, S. (2014). A numerical study of cavitation phenomenon in a flapper-nozzle pilot stage of an electrohydraulic servo-valve with an innovative flapper shape. Energy Conversion and Management, vol. 77, p. 31-39, DOI:10.1016/j.enconman.2013.09.009. [9] Kagawa, T. (1985). Heat transfer effects on the frequency response of a pneumatic nozzle flapper. Journal of Dynamic Systems, Measurement, and Control, vol. 107, no. 4, p. 332336, DOI:10.1115/1.3140744. [10] Kawashima, K., Kagawa, T. (2003). Unsteady flow generator for gases using an isothermal chamber. Measurement, vol. 33, no. 4, p. 333-340, DOI:10.1016/S0263-2241(03)00003-4. [11] Kawashima, K., Fujita, T., Kagawa, T. (1997) Unsteady flow rate measurement of air using isothermal chamber. Transaction of The Society of Instrument and Control Engineers, vol. 33, no. 3, 149 154, DOI:10.9746/sicetr1965.33.149. [12] Kawashima, K., Ishii, Y., Funaki, T., Kagawa, T. (2004). Determination of flow rate characteristics of pneumatic solenoid valves using an isothermal chamber. Journal of Fluids Engineering, vol. 126, no. 2, p. 273-279, DOI:10.1115/1.1667888. [13] Wang, T., Kawashima, K., Kagawa, T. (2007).Determination of characteristics for electrically modulated pneumatic control valves using isothermal chambers. International Journal of Fluid Power, vol. 8, no. 3, p. 5-11, DOI:10.1080/14399776.2 007.10781281. [14] Zhao, Y., Jones, B. (1991). A power air-jet actuator with piezotranslator drive stage. Mechatronics, vol. 1, no. 2, p. 231243, DOI:10.1016/0957-4158(91)90045-C. [15] PI Piezo Nano Positioning Catalog (2014/2015). from http:// www. physikinstrumente. com/info/catalogs-brochures-certificates.html, accessed at 2015-12-26. [16] IS06358-1:2013 (2013). Pneumatic fluid powerDetermination of flow-rate characteristics of components using compressible fluids - Part 1: General rules and test methods for steady-state flow. International Organization for Standardization, Geneva. [17] Slotine, J.-J.E., Li, W. (1991). Applied Nonlinear Control. Prentice-Hall Englewood Cliffs. [18] Valiloo, S., Khosrowjerdi, M.J., Salari, M. (2014). LMI based sliding mode surface design with mixed H2/H®optimization. Journal of Dynamic Systems, Measurement, and Control, vol. 136, no. 1, art. no. 11016, DOI:10.1115/1.4025553. 328 Kamali, M. - Jazayeri, S.A. - Najafi, F. - Kawashima, K. - Kagawa, T.