UDK 666.3/.7:666.3.017 ISSN 1580-2949 Original scientific article/Izvirni znanstveni članek MTAEC9, 48(3)337(2014) BIOMECHANICAL INTERACTIONS BETWEEN BONE AND METAL-CERAMIC BRIDGES COMPOSED OF DIFFERENT TYPES OF NON-NOBLE ALLOYS UNDER VERTICAL LOADING CONDITIONS BIOMEHANSKA INTERAKCIJA MED KOSTJO IN KOVINSKO-KERAMIČNIM MOSTIČKOM IZ RAZLIČNIH VRST NEPLEMENITIH ZLITIN PRI VERTIKALNIH OBREMENITVAH Ivan Tanasic, Ljiljana Tihacek Sojic, Aleksandra Milic Lemic University of Belgrade, School of Dental Medicine, Department of Prosthodontics, Doktora Subotica 8, 11000 Belgrade, Serbia doktorivan@hotmail.com Prejem rokopisa - received: 2013-05-21; sprejem za objavo - accepted for publication: 2013-08-29 The purpose of this study was to compare the mechanical properties of three metal-ceramic bridges of different types of dental alloys and to present and evaluate the possible biomechanical interactions between a marginal bone and metal-ceramic bridges during vertical loading. The research was done as an experimental study. A mandible with an intact anterior region was used. The preparation of the remaining teeth for receiving three types of porcelain-fused-to-metal (PFM) restorations was performed. Vita VMK 95 was used for all three metal-ceramic restorations. These three metal-ceramic bridges composed of different alloys, nickel and non-nickel, served as different models: the Niadur-nickelferous model, the Wiron 99-nickel model and the Wirobond C-cobalt-chrome model. The maximum compressive strain of 5 % for all three virtual models is observed in the region of central incisors. The Niadur model has the lowest mean strain (2.62 %) in comparison with the other two models. The mean strain of Wiron 99 is lower, by 0.10 %, than the mean strain of the Wirobond model. Biomechanical behavior of the presented models caused by the vertical-loading conditions is explained as an interaction between the marginal bone and the metal-ceramic bridges. All of them, nickel and non-nickel models, indicate a similar strain (deformation) distribution; however, from the biomechanical perspective, Niadur is more favorable than the other two materials. Keywords: basic alloys, deformation, biomechanics Namen te študije je bila primerjava mehanskih lastnosti treh kovinsko-keramičnih mostičkov z različnimi vrstami dentalnih zlitin ter predstavitev in ocenitev morebitne biomehanske interakcije med navidezno kostjo in kovinsko-keramičnim mostičkom med vertikalnim obremenjevanjem. Raziskava je bila opravljena kot eksperimentalna študija. Uporabljena je bila čeljust z nepoškodovanim področjem. Izvršena je bila priprava preostalih zob za namestitev 3 vrst nadomestkov (PFM) iz porcelana, spojenega na kovino. Za vse tri kovinsko-keramične nadomestke je bil uporabljen porcelan Vita VMK 95. Ti trije kovinsko-keramični mostički so bili sestavljeni iz različnih zlitin, z nikljem in brez njega, za pridobitev različnih modelov: Niadur-nikelj železo, Wiron 99-nikelj in Wirobond C-kobalt-krom. Opažen je bil največji tlačni raztezek do 5 % v območju centralnega sekalca pri vseh treh navideznih modelih. V primerjavi z drugima dvema modeloma je imel Niadur najmanjši raztezek 2,62 %. Povprečni raztezek pri Wiron 99 je bil za 0,10 % manjši kot pri modelu Wirobond. Biomehanično vedenje predstavljenih modelov pri vertikalnih obremenitvah je razloženo z interakcijo med navidezno kostjo in kovinsko-keramičnim mostičkom. Vsi modeli z nikljem ali brez njega kažejo podoben raztezek (deformacijo), razen Niadura, ki je s stališča biomehanike bolj ugoden. Ključne besede: osnovne zlitine, deformacija, biomehanika 1 INTRODUCTION alloy framework, too.11 Unlike the ceramic responsible for the aesthetics, the alloy framework should be able to Besides aesthetics1 and biocompatibility,2 dental withstand the masticatory forces.12,13 The entire metalmetal ceramics used for prosthetic reconstruction should ceramic construction should preserve the marginal-bone have good biomechanical properties.3,4 As other restora- integrity to a certain extent. tive materials, dental ceramics have disadvantages 14 The following study describes biomechanical behaviors of three different types of dental alloys under verti- mostly due to their inability to resist the functional masticatory forces that are present in the oral cavity.5,6 , , ... , , From the mechanical view point, the life-time of a cal-loading conditions, identifying the best one from the metal-ceramic bridge depends on the ceramic and alloy biomechanical perspective. The digital image correlation mechanical properties.7 In a ceramic system, the stress method (DIC) was used for a detailed strain analysis. intensity (K1) may exceed the fracture toughness (K1c).8,9 The purpose of this study was to compare the mechanical The toughness that is defined as the discrete (i.e., criti- properties of three metal-ceramic bridges of different cal) stress intensity level (Kc) is more expressed in an types of dental alloys and to present and evaluate the all-ceramic system than in metal-ceramic restorations.10 possible biomechanical interactions between the margi- During mastication, compressive, flexural, shear and ten- nal bone and metal-ceramic bridges during vertical load- sile stresses acting on the ceramic are exerted on the ing. 2 MATERIAL AND METHOD The research was performed as an experimental study. A mandible with an intact anterior region was used. The mandible was borrowed from the Laboratory for Anthropology, Institute of Anatomy, School of Medicine. According to the data from the Laboratory archive, the mandible donor was female, in her late 60s. The mandible was previously prepared and exposed to occlu-sal loading. The preparation procedure was followed by placing the mandible in a saline solution, the drying process and the preparation of the anterior abutment teeth.15 The preparation of the remaining teeth for receiving three types of the porcelain-fused-to-metal (PFM) restorations was performed. Vita VMK 95 was used as the "ceramic of choice" for all three metal-ceramic restorations. Nevertheless, these three metal-ceramic bridges were composed of different alloys: Niadur-nickelferous (a Cr-Ni alloy), Wiron 99 (a Ni-Cr alloy) and Wirobond C (a Co-Cr alloy). After the first metal-ceramic bridge (Niadur + Vita 95) was obtained, it was pressed with elastomer gum in a standard tray to get an elastomer mold (Figure 1) for the next two metal-ceramic bridges. In this way, three models with similar forms were obtained. The narrow space between the dental roots and the alveoli was coated with a silicone membrane, similar to a periodontal ligament, to reduce the vertical force to a certain extent (Figure 2).The mandible with the metal- Figure 2: Thin silicone layer imitating a periodontal ligament Slika 2: Tanek sloj silikona posnema parodontalne vezi ceramic bridges positioned in situ was used for obtaining three experimental models: the Niadur model, the Wiron 99 model and the Wirobond C model. Each model had a metal-ceramic bridge made of a different type of alloy. After the preparation procedure, the model was exposed to vertical loading. The average masticatory force was reported to vary between 11 and 150 N, whereas the force peaks were reported to be 200 N in the anterior, 350 N in the posterior and 1000 N in the subjects with parafunctional habits. The load of 300 N was used for the in-vitro experimental analyses. A vertically directed load was applied onto the incisal and occlusal surfaces of Figure 1: Elastomer mold (impression) for shaping equal metal-ceramic bridges Slika 1: Forma za elastomer (odtisek), ki se uporablja za enake kovin-sko-kerami~ne mosti~ke Figure 3: Mandible restored with a metal-ceramic bridge composed of Niadur Slika 3: Obnovljena ~eljust s kovinsko-kerami~nim mosti~kom iz Niadura Table 1: Strain values (e) and fracture toughness for three mandible models restored with metal-ceramic bridges composed of different base alloys Tabela 1: Raztezki (e) in lomna zilavost pri treh ~eljustnih modelih, obnovljenih s kovinsko-kerami~nimi mosti~ki iz zlitin z razli~no osnovo Tested model (F = 300 N) emin/% emax/% mean strain (%) No. of measurements before a fracture of the ceramic or marginal bone NIADUR 0.25 5 2.62 6 WIRON 99 0.5 5 2.75 5 WIROBOND C 0.7 5 2.85 9 the metal-ceramic bridges. The measuring was performed three times for each model, but for each new measurement the next model was used. So, every metal-ceramic model was loaded three times with a gap of 10 min between the measurements. After three cycles of the preliminary loading of different models, they were being loaded until a fracture occurred. The numbers of the cycles leading to the fractures are presented in Table 1. The strain measurement was performed using the equipment from the GOM manufacturer.16 When a model was loaded, a camera photographed the model stage and the Aramis software processed the obtained data and visualized the strain field. This is represented with virtual models (Figures 3 to 5). 3 RESULTS The maximum compressive strain of 5 % in all three virtual models is observed in the region of the central incisors. All three models have the same strain propagation in the upper part of the mandible body. Nevertheless, the marginal bone in the Wirobond model suffered from a greater overall strain in comparison with the other two Ni-Cr models. This can be explained with the fact that the marginal bone of almost every abutment of the Wirobond model deforms to a greater extent (Figure 5) than in the other two cases. The strain values detected on the vestibular surfaces of the metal-ceramic bridge framework are slightly higher in the Wirobond model. Nevertheless, the strain may exceed 3 % in the contact region between the central incisors in the Co-Cr model. The Vita 95 ceramic in the Wirobond model was fractured after nine cycles of the vertical-loading exposure which is slightly better than in the other two models (Table 1). Niadur does not induce a higher strain than Wiron 99 (Figures 3 and 4). Also, it is noticed that the Niadur model has the lowest mean strain (2.62 %) in Figure 5: Mandible restored with a metal-ceramic bridge composed of Wirobond C Slika 5: Obnovljena ~eljust s kovinsko-kerami~nim mosti~kom iz Wirobonda C comparison with the other two models (Table 1). The highest strain in all three virtual models is mainly concentrated in the region of the anterior teeth, especially the incisors. In this region, just below the marginal edge of the metal-ceramic bridge, we notice the highest strain of 5 %, presented with line section 0. Figure 6 shows the variations in the strain within the section line connecting the two points with the shortest distance (43.9 mm): the incisal edge of the metal-ceramic bridge and the lowest point of the mandible body. The diagram in Figure 6 indicates that the section line in the region of the metal-ceramic bridge and the marginal bone has the highest strain value in the Wiron 99 model. Although the overall strain in the Wirobond model has a similar distribution to the one in the Wiron 99 model, the mean strain for Wiron 99 is by 0.10 % lower than for the Wirobond model. 4 DISCUSSION For the elderly, losing posterior teeth may influence their chewing ability or cause an abrasion of the anterior teeth and a loss of the vertical dimension. In such a situation, fully covering porcelain-fused-to-metal crowns Figure 4: Mandible restored with a metal-ceramic bridge composed of Wiron 99 Slika 4: Obnovljena ~eljust s kovinsko-kerami~nim mosti~kom iz Wirona 99 Figure 6: Diagram of the strains within the section lines positioned by the software for every model Slika 6: Diagram raztezkov vzdolž odsekov, ki jih dolo~i programska oprema za vsak posamezni model or metal-ceramic bridges may be the best choice, having advantages over an all-ceramic system because the fracture failure is more expressed in an all-ceramic system than in metal-ceramic restorations.17 It is known that most of the elderly persons are not so interested in a removable partial denture because of its discomfort,18 also rejecting implants in conventional therapy, probably because their expensiveness or surgical procedure. Thus, they occasionally choose a simple solution, deciding not to have all 28 teeth but to save or restore what is left. This study took into account the fact that 8-10 teeth in a jaw (with a minimum of 2 premolars) are enough for elderly persons.19 As elderly persons with shortened dental arches mostly bite with the anterior teeth, these teeth have to be restored because of the damages (the teeth wear) on their incisal and vestibular surfaces.2021 Many in-vitro techniques for evaluating the mechanical properties of dental alloys or ceramics have been proposed.22,23 In spite of their apparent simplicity, indentation techniques are burdened with a number of shortcomings related to the specimen preparation, analytical techniques and mathematical analyses.24 This in-vitro study tends to evaluate and measure the strains caused by loaded metal-ceramic bridges consisting of different alloys. The novelty in this research is that DIC visualizes biomechanical impacts of the frameworks of various alloys on the mandible under vertical loading. This is an elegant and innovative method for researching dental biomechanics that can better explain a distribution of exerted vertical loads. Due to the fact that the applied model (mandible+fixed restorations) is most similar to natural circumstances, it has a great advantage over a standardized specimen. The study is not a conventional investigation with a standardized specimen. It is an in-vitro investigation where a cadaveric mandible model is loaded within the boundary conditions.25 A silicone layer was used for the amortization of the applied loads, simulating the perio-dontal ligament and physiological conditions.26 Also, a silicon mold was used for standardizing the metal-ceramic frameworks of three different alloys. In this way, similar metal-ceramic models could be obtained and the investigation was conducted with high precision and under the same conditions. The number of loading cycles exerted before the ceramic fracture indicates the fracture toughness27 of the applied metal-ceramic bridges. Niadur and Wiron 99 are non-precious alloys, very often used in contemporary dental practice because of their low costs. In dentistry, cobalt-chromium alloys are frequently used for partial denture frameworks. Adition-ally, Co-Cr alloys have a substantially higher biocompa-tibility than Ni-Cr alloys1128 29 and, for this reason, they are much more favorable in dental practice. As can be seen in Table 1, the Co-Cr model is more resistant to the ceramic fracture than the other two models. This may be explained with the fact that the bond strength is higher in Co-Cr alloys, which is in correlation with the previous finding.30 This is why the Co-Cr alloy was the alloy of choice when compared with Ni-Cr alloys. Besides other factors (the metal-ceramic bond strength and the elastic modulus) the extent of the marginal-bone loss may influence the rate of clinical survival of metal-ceramic bridges.11,31 The study examined and compared three types of ceramics and their impacts on the marginal bone and it was found that there is no significant difference in the strain distribution between the nickel and non-nickel alloys. It was found that a wider strain field is detected on the loaded Co-Cr alloy than on the Ni alloys (Figure 3). In this case, every abutment suffered from the same strain intensity. Nevertheless, both nickel alloys (Niadur and Wiron 99) have a similar strain distribution with the highest strain in the region of central incisors (Figures 1 and 2). Although dental Co-Cr alloys are widely used in dental practice due to their good mechanical properties and excellent corrosion resistance,32 this study does not give an advantage to one over the other alloy. However, it is good to know that a Co-Cr based alloy may be an excellent alternative, especially when combining fixed and removable prostheses.33 5 CONCLUSION Within the limitations of this study the following conclusions may be reached: • The biomechanical behaviors of the presented models caused by vertical-loading conditions are explained as the interactions between the marginal bone and metal-ceramic bridges; • The aforementioned biomechanical interactions are described as the force-induced strains in the upper part of the mandible bone tissue; • All the Ni-Cr and Co-Cr models indicate a similar strain distribution, but Niadur is more favorable than the other two from the biomechanical perspective; • Wiron 99 has a larger impact on the marginal bone than the Wirobond C or Niadur alloys; • The overall strain has a larger impact in the upper part of the mandible in the case of the Wirobond C model; • The maximum strains in all the virtual models have the same PIC values that do not exceed 5 %; • All three semicircular metal-ceramic bridges show the highest strain in the central position between the first incisors. 6 REFERENCES 1 H. T. Shillingburg, S. Hobo, L. D. Whitsett, R. Jacobi, S. E. Brackett, Fundamentals of fixed prosthodontics, 3rd ed., Quintessence Publishing Co., 1997, 181-210 2 T. E. Donovan, G. C. Cho, Predictable aesthetics with metal-ceramic and all-ceramic crowns: the critical importance of soft-tissue management, Periodontol 2000, 27 (2001), 121-30 3 M. Persson, M. Bergman, Metal-ceramic bond strength, Acta Odon-tol Scand, 54 (1996), 160-165 4G. Libby, M. R. Arcuri, W. E. LaVelle, L. Hebl, Longevity of fixed partial dentures, J Prosthet Dent., 78 (1997), 127-131 5 H. Yilmaz, C. Aydin, B. E. Gul, Flexural strength and fracture toughness of dental core ceramics, J Prosthet Dent., 98 (2007) 2, 120-128 6 A. J. Raidgrodski, Contemporary all-ceramic fixed partial dentures: a review, Dent Clin North Am., 48 (2004) 8, 531-544 7 N. H. J. Creugers, A. F. Käyser, M. A. van't Hof, A meta-analysis of durability data on conventional fixed bridges, Community Dent Oral Epidemiol, 22 (1994), 448-452 8 J. B. Quinn, V. Sundar, I. K. Lloyd, Influence of microstructure and chemistry on the fracture toughness of dental ceramics, Dent Mater., 19 (2003), 603-611 9 H. Fischer, R. Marx, Fracture toughness of dental ceramics: comparison of bending and indentation method, Dent Mater., 18 (2002), 12-19 10 J. J. Mecholsky, Fracture mechanics principles, Dent Mater., 11 (1995), 111-2 11 C. J. Goodacre, G. Bernal, K. Rungcharassaeng, J. Y. K. Kan, Clinical complications in fixed prosthodontics, J Prosthet Dent., 90 (2003) 1, 31-41 12 R. G. Craig, J. M. Powers, J. C. Wataha (editors), Dental materials -properties and manipulations, 7th ed., Mosby-Year Book, St. Louis 2000 13 M. Ozcan, Fracture reasons in ceramic-fused-to-metal restorations, J Oral Rehabil., 30 (2003) 3, 265-269 14 C. Field, Q. Li, W. Li, M. Thompson, M. Swain, Prediction of mandibular bone remodelling induced by fixed partial dentures, J Biomech., 43 (2010), 1771-1779 15 Lj. Tihacek-Sojic, A. Milic-Lemic, I. Tanasic, N. Mitrovic, M. Milosevic, Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities, Gerodontol., 29 (2012) 2, e851-e857 16 GOM: http://www.gom.com/ 171. Denry, J. R. Kelly, State of the art of zirconia for dental applications, Dent Mater., 24 (2008) 3, 299-307 18 N. Jepson, P. F. Allen, Short and sticky options in the treatment of the partially dentate patient, Br Dent J., 187 (1999), 646-652 19 A. F. Käyser, Minimum number of teeth needed to satisfy functional and social demands, In: A. Frandsen (ed.), Public Health Aspects of Periodontal Disease, Quintessence, Chicago, IL 1984, 135-147 0P. T. Sarita, C. M. Kreulen, D. Witter, N. H. Creugers, Signs and symptoms associated with TMD in adults with shortened dental arches, Int J Prosthodont, 16 (2003) 3, 265-270 1 D. J. Witter, N. H. Creugers, C. M. Kreulen, A. F. de Haan, Occlusal stability in shortened dental arches, J Dent Res., 80 (2001) 2, 432-436 2 J. M. Scolaro, A. L. do Valle, Bonding ceramic to metal: A comparison using shear test, Rev Fac Odontol Bauru, 10 (2002) 1, 57-62 3W. J. Garbelini, G. E. Henriques, M. Jr. Troia, M. F. Mesquita, C. C. Dezan, Evaluation of low-fusing ceramic systems combined with titanium grades II and V by bending test and scanning electron microscopy, J Appl Oral Sci., 11 (2003) 4, 354-60 4 S. S. Scherrer, I. L. Denry, H. W. A. Wiskott, Comparison of three fracture toughness testing techniques using a dental glass and a dental ceramic, Dent Mater., 14 (1998), 246-255 51. Tanasic, A. Milic-Lemic, Lj. Tihacek-Sojic, I. Stancic, N. Mitro-vic, Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method, Biomech Model Mechanobiol., 11 (2012) 6, 751-758 6 M. Kaku, K. Uoshima, Y. Yamashita, H. Miura, Investigation of peri-odontal ligament reaction upon excessive occlusal load - osteopontin induction among periodontal ligament cells, J Periodontal Res., 40 (2005) 1, 59-66 7 H. Wang, P. Pallav, G. Isgro, J. Albert Feilzer, Fracture toughness comparison of three test methods with four dental porcelains, Dent Mater., 23 (2007) 7, 905-910 8 J. W. McLean, Evolution of dental ceramics in the twentieth century, J Prosthet Dent., 85 (2001) 1, 61-66 'A. S. Hiyasat, O. M. Bashabsheh, H. Darmani, Elements released from dental casting alloys and their cytotoxic effects, Int J Prostho-dont, 15 (2002) 5, 473-478 0 J. Lenz, S. Schwarz, H. Schwickerath, F. Sperner, A. Schafer, Bond strength of metal-ceramic systems in three-point flexure bond test, J Appl Biomater., 6 (1995) 1, 55-64 1 M. Ozcan, W. Niedermeier, Clinical study on the reasons for and location of failures of metal-ceramic restorations and survival of repairs, Int J Prosthodont, 15 (2002) 3, 299-302 2 A. Carek, J. Živko-Babic, Z. Schauperl, M. Jakovav, Mechanical properties of Co-Cr welded alloy, J Dent Res., 89 (2010), 745 3S. Viennot, F. Dalard, G. Malquarti, B. Grosgogeat, Combination fixed and removable prostheses using a CoCr alloy: a clinical report, J Prosthet Dent., 96 (2006) 2, 100-103